Fireplace Requirements - Jøtul GI 350 DV Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Hide thumbs Also See for GI 350 DV:
Table of Contents

Advertisement

18 3/4”
575mm
381 mm
Figure 2. Universal GI 350 DV dimensions.
Minimum Fireplace
Requirements
The Universal GI 350 DV gas insert has been specifi-
cally designed to be installed into a solid fuel
burning factory built fireplace or a code approved
solid fuel burning masonry fireplace with a tile flue
liner. An acceptable fireplace cavity must have the
minimum dimensions specified in fig. 3.
Do not modify or alter the construction of the
gas insert or any of its components to enable it to fit
into a fireplace. Any modification of the insert will
void the warranty, certifications and approvals of the
unit and could be dangerous.
9 3/8”
238 mm
5 5/8”
143 mm
2 1/2”
64 mm
Height
15”
Adj.
3”
76 mm
5”
127 mm
18 3/8”
466 mm
16”
406 mm
E
A: A: A: A: A: Opening Width = 31" (787 mm)
without leveling brackets = 30" (762 mm)
B: B: B: B: B: Opening Height = 20" (520 mm)
with Scan 65i 1" riser = 21" (533 mm)
with Scan 65i 2" riser = 22" (559 mm)
C: C: C: C: C: Back Wall Width = 19" (483 mm)
without levelling brackets = 18" (457 mm)
D: D: D: D: D: Back Wall Height = 19" (483 mm)
w/ Scan 65i 1" riser = 20" (508 mm)
w/ Scan 65i 2" riser = 21" (533 mm)
E: E: E: E: E: Depth = 16" (406 mm)
Figure 3. Minimum fireplace cavity dimensions.
19”
483 mm
17 1/2”
444 mm
4 1/4”
108 mm
29”
737 mm
30 1/2”
775 mm
22”
559 mm
13 1/2”
343 mm
19 1/2”
495 mm
Glass Frame
Latches
D
B
C
A
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents