Blower Controls; Annual Cleaning - Jøtul GI 350 DV Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Hide thumbs Also See for GI 350 DV:
Table of Contents

Advertisement

Figure 33.
GI 350 DV
Burner
Control
Switch.
Figure 34.
GI 350 DV and

Blower Controls.

Blower Function
The blower is controlled by a heat-activated switch
(snapstat) that will only function if the blower control
switch is in either the HI or LOW setting. The blower
will not operate until the sensor reaches 120°F. This
will take about 10 minutes in most installations.
Conversely, once the burner is off, the blower will
continue to operate until the snapstat cools down to
110°F and shuts off power to the blower.
If the blower is not needed, place the blower
control switch in the OFF position and the snapstat
will not function.
C C C C C A A A A A U U U U U T T T T T ION:
ION:
ION:
ION:
ION: Alw
Alw
Alwa a a a a y y y y y s unplug
Alw
Alw
per
per
perf f f f f orming an
orming an
orming an
y ser
y ser
per
per
orming an
orming any ser
y servic
y ser
24
BURNER
ON
OFF
TSTAT
MANUAL
OFF
AUTO
BLOWER
s unplug the Blo
s unplug
s unplug
s unplug
the Blo
the Blow w w w w er when
the Blo
the Blo
er when
er when
er when
er when
vic
vic
e on
e on
the fir
the fir
eplace e e e e . . . . .
eplac
eplac
vic
vice on
e on
e on the fir
the fir
the fireplac
eplac
Maintenance
The GI 350 DV gas fireplace and its venting system
should be inspected before use and at least annually
by a qualified service technician.
IMPORTANT:
ALWAYS TURN OFF THE GAS SUPPLY TO THE FIREPLACE
AND UNPLUG THE FORCED AIR BLOWER BEFORE ANY
SERVICE WORK IS PERFORMED ON THE FIREPLACE.

Annual Cleaning

Vent System
The entire vent system, including the chimney,
should be inspected and cleaned every year. If the
intake and exhaust venting is disassembled for any
reason, it should be reassembled and sealed accord-
ing to the vent manufacturer's instructions provided
at the initial installation.
Burner and Log Set
Periodically inspect the Firebox, Valve Compartment,
Blower Assembly and Convection Airways to BE
CERTAIN THAT THE FLOW OF COMBUSTION AND
VENTILATION AIR IS UNOBSTRUCTED.
The firebox should be vacuumed at least annu-
ally to remove any surface build up. Use a soft brush
attachment and handle the logs carefully as they are
fragile. Be sure to vacuum or wipe off the pilot
assembly, burner orifice and burner tube.
Glass Care
Clean the glass as necessary. Wipe the surface with a
clean, dampened, soft cloth. Follow with a dry, soft
towel. Take care not to scratch the glass surface.
Scan 65 i: Sliding Glass Panel Care
The black coating around the perimeter of the back of
this glass is especially prone to fingerprinting when
handled. Fingerprints may be wiped clean with a soft
cloth and any common window cleaning solution.
WARNING: DO NOT USE ABRASIVE CLEANERS ON THE
GLASS. NEVER CLEAN THE GLASS WHEN IT IS HOT.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents