Frequent Maintenance Procedures - Cornelius JetSpray JS7C Operator's Manual

Jetspray visual display dispenser
Table of Contents

Advertisement

FREQUENT MAINTENANCE PROCEDURES

C
B
LEANING THE
1.
Before removing the bowls, turn off both the refrigeration and spray switches. Unplug the unit from
its power source.
2.
Drain any beverage left in the bowls.
3.
Remove pinch tube by pushing handle until it stops. Pull up on the pinch tube until it is free, then
remove the handle (see Page 3). Lift off the bowls, drip trays and covers. Clean them thoroughly.
4.
Clean as described in "Cleaning the Dispenser" on page 4.
5.
After cleaning, assemble as described in "To Assemble" on page 4. Replace the push handle and
insert the pinch tube into the bowls.
C
C
LEANING THE
1.
To remove the condensation drains, push in on the front panel, just under the drain and pull down
with fingers, as shown in Figure 8.
2.
To replace the condensate drains, hold the drain against the front panel under the rectangular hole
(opening in side of drain should be toward front panel). Push up through the hole until the drain
snaps into place (see Figure 9).
S
U
ANITIZING THE
After cleaning, add one gallon of water at a temperature of between 75
tablespoon of approved powdered chlorine sanitizer* to a pint of water and when dissolved, pour into bowl.
Replace the lid and run the unit for two or three minutes. Shut off the unit and drain the contents through the
pinch tube valve.
*Diversey-MultiChlor or equivalent powder or liquid sanitizer.
CAUTION: DO NOT run the refrigeration system while sanitizing the unit.
© 2009, IMI Cornelius Inc.
OWLS
D
ONDENSATE
RAINS
NIT
Figure 8
Figure 9
o
F and 100
- 7 -
Operator's Manual
o
F to the bowl. Mix one
Publication Number: 620047630OPR