LG RC9042AQ3Z Owner's Manual page 10

Lg heat pump dryer
Hide thumbs Also See for RC9042AQ3Z:
Table of Contents

Advertisement

I
nstallation Instructions
Connecting water supply hose
The dryer must be connected to the cold water tap using the new water supply hose. Do not use old
hoses.
Note
• Water supply pressure must be between 100 kPa and 1000 kPa (1.0 - 10.0 kgf / cm
• Do not strip or cross-thread when connecting inlet hose to the valve.
• If the water supply pressure is more than 1000 kPa, a decompression device should be installed.
• Periodically check the condition of the hose and replace the hose if necessary.
Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found.
Short
hose
Y connector
A
10
Step1 : Check rubber seal in the inlet hose.
Two rubber seals are supplied with the water inlet
hoses.
They are used for preventing water leaks.
Hose
Make sure the connection to the tap is sufficiently
connector
tight.
Rubber
seal
Y connector
Step2 : Check the installation environment.
A type
-. When using both washer and dryer with one
water tap.
Assemble Y connector and short hose.
Connect the female part of the short hose to the
water tap.
Connect the male part of Y connector to the
female part of the long hose.
Connect another male part of Y connector to the
female part of the inlet hose of washer.
B type
-. When using only the dryer from one tap.
Connect the female part of the long hose to the
water tap.
• Connect the water supply hoses to the COLD
Long
water tap tightly by hand and then tighten another
hose
2/3 turn with pliers.
B
Note
• After connecting the inlet hose to the water tap,
turn on the water tap to flush out foreign sub-
stances (dirt, sand or sawdust) in the water
lines. Let the water drain into a bucket, and
check the water temperature.
).
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc9042bq3zRc9042cq3zRc9042dq3zRc9042eq3z

Table of Contents