Installation Information

ELECTRICAL REQUIREMENTS

Install the Power Transformer
Wolf outdoor grills have a power transformer for the
lights and igniters which is concealed in a stainless
steel box with an attached power supply cord.
Cart Application - Two mounting screws are provided
for mounting the transformer inside, on the floor of the
cart.
Built-in Application - Secure the transformer box in a
dry location, away from the grill firebox and excessive
heat area, but within 2' (.6 m) of the right rear grill open-
ing.
NOTE: Do not install the transformer box inside the
insulating liner. The transformer box must be secured
away from excessive heat and in a dry location.
Make the transformer connections to the wire harness
located at the right rear of the grill to the harness of the
transformer box.
Plug the power cord from the transformer into a proper-
ly grounded GFCI 120 V AC outlet. The outlet must be
located within 6' (1.8 m) of the transformer.

Rotisserie Motor

The rotisserie motor requires a GFCI 120 V AC electri-
cal supply. The 9' (2.7 m) power cord on the motor is
equipped with a 3-prong grounded plug for protection
against shock hazard.
SHOCK HAZARD!
• THE POWER TRANSFORMER AND THE ROTIS-
SERIE MOTOR SUPPLIED WITH OUTDOOR GAS
GRILLS
ARE
EQUIPPED
GROUNDING
PLUGS
AGAINST SHOCK HAZARD.
GROUNDING PLUGS SHOULD BE PLUGGED
DIRECTLY INTO PROPERLY GROUNDED 3-
PRONG OUTLETS. DO NOT CUT OR REMOVE A
GROUNDING PRONG FROM A PLUG.
• DO NOT USE AN EXTENSION CORD OR TWO-
PRONG ADAPTER.
#814144 - Revision A - July, 2009
WITH
3-PRONG
FOR
PROTECTION
THE 3-PRONG
Outdoor Grill (OG) Series

GAS SAFETY REQUIREMENTS

NOTE: The outdoor gas grill must be connected to a
regulated gas supply by a qualified technician and in
accordance with local codes and ordinances.
Each appliance is set and tested at the factory for the
type of gas supply to be used. Identify the type of gas,
either natural gas or LP gas, and make sure that the
type of gas specified on the product rating plate match-
es the gas being supplied to the grill.
Conversion kits are available for both LP and natural
gas grills. Contact a Wolf dealer or distributor for more
information.

GAS SUPPLY REQUIREMENTS

Connect the grill to the gas supply line. The gas supply
line must be of adequate size to properly service all gas
appliances. Wolf recommends the use of a minimum
1/2" (13) I.D. commercial type flex hose from the gas
supply line to the grill connection. The units will operate
on 1/2" (13) pipe to a maximum run of 30' (9 m). All
plumbing to the flex hose must be 3/4" (19) minimum
I.D. pipe.
NOTE: For complete gas shutdown, an external gas
shut-off valve must be located near the appliance in an
accessible location (See Figure 2-2).
OPEN POSITION
TO APPLIANCE
Figure 2-2. External Gas Shut-off Valve
ENSURE THAT THE GAS SUPPLY HOSE DOES
NOT COME IN CONTACT WITH ANY HOT SURFACE
OF THE GRILL!
2-6
GAS SUPPLY
LINE