Theory of Operation
The gas and air travel through the venturi
tube and the mixing tube where the gas
and air mix together. The gas and air
mixture then enters into the burner body.
(See Figure 3-6)
The gas and air mixture then exits out of
the burner ports where it mixes with "sec-
ondary air.", and the ports closest to the
flash tube feed the gas/air mixture into
the flash tube. With the glow igniter
energized, the gas/air mixture in the flash
tube ignites.
(See Figure 3-7)
NOTE: A lanyard is supplied with OG
appliances to hold a lit match should the
glow igniter be inoperable.
The ignition at the flash tube subsequent-
ly ignites the gas and air mixture at the
other burner ports. With the proper gas
and air mixture, a flame of natural gas
should be blue with a deep blue inner
cone and have no trace of yellow flame;
with liquid propane gas some orange tip-
ping is acceptable.
(See Figure 3-8)
NOTE: The flame should be odorless
and completely free of dangerous gases.
#814144 - Revision A - July, 2009
Outdoor Grill (OG) Series
Valve
Shutter
G A S
Control
Orifice
Knob
Figure 3-6. Venturi, Mixing Tube and Burner Body
Glow Igniter
Valve
Shutter
G A S
Control
Orifice
Knob
Glow Igniter
Valve
Shutter
G A S
Control
Orifice
Knob
Figure 3-8. Full Ignition and Proper Flame
3-6
Venturi
Mixing Tube
Flash Tube
Ignition
Venturi
Mixing Tube
Figure 3-7. Ignition
Flash Tube
Proper Flame
at Burner Ports
Venturi
Mixing Tube
Burner Body
G A S
Regulator
Burner Body
G A S
Regulator
Burner Body
G A S
Regulator

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Og42Og36Og30-lpOg42-lpOg30

Table of Contents