Mantels & Surrounds - Montigo R320-ST Installation & Maintenance Manual

R-series-st indoor residential fireplace
Hide thumbs Also See for R320-ST:
Table of Contents

Advertisement

R320-ST & R420-ST Power Vent Indoor Gas Fireplace
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models
of fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discoloration or premature failure of T.V. and
radio components.
Side wall clearances are 6". Combustible surrounds may be installed
with 6" clearance to the side of the fireplace as shown in Figure2Sec.7.
15 1/2" Non-Combustible
Facing Material
Non-combustible Header
Figure 2 Sec.7 Combustible surrounds.
Note: Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.
Page 22
Installation
Drywall Sheetrock
15½"
6"
XG0774 - 150121