Venting Components; Installation Of The Pvvex58-300 External Roof Mounted Power Vent Module - Montigo R320-ST Installation & Maintenance Manual

R-series-st indoor residential fireplace
Hide thumbs Also See for R320-ST:
Table of Contents

Advertisement

R320-ST & R420-ST Power Vent Indoor Gas Fireplace

Venting Components

The following venting components and associated Montigo part
numbers are available for the PVVEX58-300:
A - Termination
PVVEX58-300
B - Rough-in Frame
Supplied with PVVEX58-300
C - Flex Sections
PLF-1 (12" Section)
PLF-2 (24" Section)
PFL-3 (36" Section)
PFL 4 (48" Section)
D - Rigid Sections
PEXT-1 (12" m/f Section)
PXT-20 (20" Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90º Elbow
PEL-90FF (f/f 90º Elbow
PEL-90FM (f/m 90º Elbow)
PEL-45FM (f/m 90º Elbow)
F - Power Cord
EPVH10-10 foot power cord & harness
Harnesses
EPVH20-20 foot power cord & harness
EPVH30-30 foot power cord & harness
EPVH40-40 foot power cord & harness
EPVH50-50 foot power cord & harness
EPVH60-60 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH90-90 foot power cord & harness
EPVH100-100 foot power cord & harness
Connectionandinstallationoftheventcomponentsshould
adheretothefollowingguidelines:
■ Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue.
■ Ensure the pipe ends male to female slide in a minimum
of 1 1/2" of overlap.
■ Ensure all horizontal runs are supported with a minimum
of 3 supports per 10' of venting.
■ When hanging/ supporting venting, ensure that 1" clearance
is maintained on all sides to any combustible material.
■ Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
■ Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots.
■ Montigo recommends the use of a flex section for the final
pipe connected directly to the fireplace offering greater
flexibility of installation and absorption of movement.
■ All exterior joints in venting should be sealed with high heat
silicone RV230.
Page 14
Installation
Installation of the PVVEX58-300 External Roof
mounted power vent module.
Note: See power vent manual for installation instructions.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable.
XG0774 - 150121

Advertisement

Table of Contents
loading

This manual is also suitable for:

R420-st

Table of Contents