Montigo R520 Installation, Operation & Maintenance Manual

Indoor c-view residential fireplace

Advertisement

C-View Residential Fireplace
BF-Series SS Gas Fireplace
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns. Please keep children away from the fireplace
at all times.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG0771
Canadian Heating Products Inc. Langley, BC V4W 4A
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
®
C
US
Montigo Del Ray Corp. Ferndale, WA 98248
f i r e f e a t u r e
www.montigo.com
R520
R620
Warning:
mation in these instructions is not
followed exactly, a fire or explosion
may result causing property dam-
age, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Installer: Leave this manual
with the appliance.
Consumer: Retain this
manual for future reference.
Indoor
Indoor
If the infor-
070111

Advertisement

Table of Contents

Troubleshooting

loading

Summary of Contents for Montigo R520

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. • Consumer: Retain this ® manual for future reference. XG0771 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 070111...
  • Page 2: Table Of Contents

    Installation, Operations and Your new FireFeature gas fireplace will give you years of durable, reli- Maintenance manual. Pay special attention to all cautions, warnings, able use. Welcome to the Montigo family of gas fireplace products. and Important warnings. Safety Alert Key: •...
  • Page 3: Introduction

    Children and adults should be alerted to the hazards  venting runs. of the high surface temperature, which could cause The R520 is rated for Natural Gas at 80,000 BTU/H (23.2 Kilowatts)  burns or clothing ignition. Input, and Propane at 65,000 BTU/H (18.9 Kilowatts). Use 5”/10" dia Young children should be carefully supervised when ...
  • Page 4: Dimensions

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation WARNING! WARNING When this appliance is installed directly on Any combustible The C-View Residential unit is a power vented fireplace system. Under...
  • Page 5: Vent Installation

    Installing the Residential’s Terminations with Frame Power Vent Termination Frame the termination opening for fireplace models, R520 and R620, Pages 6 to 9. (Vertical & Horizontal Vent Runs) Fasten the termination and its frame in place using a minimum of 4 screws, See Figure 2 below.
  • Page 6 Residential fireplace, and Use of other venting. non-certified parts will void the Montigo warranty, and may impede the opera- For vertical installations the longest vent run is 140 feet with a limit of 6 ...
  • Page 7: Exterior Power Vent Installation

    1" clearance around all vent pipe to any combustible materials. When the top of the Constructed Chase. Also, at this point install the using Montigo flex pipe or rigid elbows ensure that the inner pipe is Electrical harness, (EPVH-(10-100) that will communicate with fastened with three metal screws as well as the outer pipe.
  • Page 8 C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Step 5. Install the Power Vent, Roof-top Stainless steel cover over the Installed Rough-in Kit. (You can see the Electrical harness con- nector in the top right corner).
  • Page 9 The C-View Residential Series fireplace use a Designated coaxial vent system designed specifically for the Residential fireplace, and Use of other Step 8. non-certified parts will void the Montigo warranty, and may impede the opera- tion of the fireplace. Install (3) three stainless steel fasteners around Power Vent...
  • Page 10: Vent Components

    For horizontal installations the longest vent run is 100 feet with a limit of 4  using the Montigo flex pipe ensure that the inner pipe is fasten with -90° Elbows, or 8 - 45° Elbows. For longer runs contact Montigo.
  • Page 11 ■ Opening Size must be: 14 1/2" x 14 1/2". ■ Maximum allowed vent run is 100 feet. (Refer to Montigo Reference Document, XG1035) for all Possible variations not described here. Figure 5b. Installation of Rough-in Kit ■...
  • Page 12 C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Step 5. Communication Securely fasten the bottom Collar pan into the Rough-in frame Harness. TOP of Power Vent, using the existing hardware, (4-pcs). Tighten the Strain Relief nut (Note Quantity of onto Strain relief fitting.
  • Page 13: Converting To Top / Rear Vent

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Converting to Top Vent / Rear 5” Inner Flue Collar, Typ. Vent All models (with gasket) All C-View Residential are boxed and shipped as Top Vent fireplaces.
  • Page 14: Installing The Gas Line

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Note: No gas is needed to prove the system.  Note: After gas line is connected, each appliance connection, The control panel is supplied with a power cord plug in.
  • Page 15 C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Step 1. To ensure your glass viewing area is at the optimum height, follow the Example below, Figure 16. Example: If you wish to have the bottom edge of the glass to be 24", the top of the platform will be 13".
  • Page 16 Non-Combustible cement board, Pre-drill for Nail fasteners (supplied by Montigo) or Equiv. Combustible framing Clearance required for expansion of the fireplace when in operation. 1/8” Figure 16c. Non-combustible Board over the Fireplace, (supplied by Montigo). Part No. XG0771 - 0070111 Page 16...
  • Page 17: Finishing Around The Fireplace

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Step 5. As shown in Figure 6d; Cut standard Gyproc / Drywall board to complete the installation of the surround. Fit the edge of the board to the rim around the fireplace opening.
  • Page 18: Installation Of Electrical Supply

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation Installation Of Electrical Supply Wall Switch 6 - conductor 110V Power Supply The C-View Residential Fireplace is supplied with an external electri-...
  • Page 19 C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Installation If you do not follow these instructions exactly, a fire or WARNING! explosion may result causing property damage, personal injury or loss of life.
  • Page 20: Operation

     This fireplace will not operate unless the correct air movement is detected by our control system..  Please consulted with your contact person at Montigo should you have any problems with your start up.  Operation: With Honeywell Intermittent Pilot...
  • Page 21: Maintenance

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Maintenance Removing and Installing Removing the door: Follow the (4) four steps to remove, or install the C-View Residential the Door trim and Door fireplace door.
  • Page 22 The C-View Residential fireplace has the option of installing the cul- tured rocks which mimic real stone. These may be spaced at random, or in a visual pattern of your preference. See the Montigo web site for photographs and ideas.
  • Page 23: Cleaning

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Maintenance Troubleshooting CAUTION! Fireplace gas control must be in the “OFF” position and pilot  HONEYWELL SV9500 /9600 and main burners extinguished when cleaning appliance with Troublshooting Sequence a vacuum.
  • Page 24: Troubleshooting

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Maintenance Troubleshooting the Power Vent Gas Control Valve System: Honeywell (Q3450) Pilot Assembly 1. Plug the power cord into a 110 Volt outlet.
  • Page 25: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 26 C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Appendix A - Powervent Locations The Vertical EPVRR Power Vent The Horizontal EPVRW Power Vent Wall 30” Min. Eaves / Overhang Wall 30”...
  • Page 27 C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Appendix A - Powervent Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony clearance above paved sidewalk or a paved driveway located on public property †...
  • Page 28: State Of Massachusetts

    C-View Residential R520-R620 Series Indoor Gas Fireplace f i r e f e a t u r e Appendix B State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows:...
  • Page 30 XG0771 - 010610 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...

This manual is also suitable for:

R620

Table of Contents