Environmental Limits; Ambient Temperature; Figure 1 Location Of Hda Temperature Check Point - Seagate ST4000NK0001 Product Manual

Kinetic hdd
Table of Contents

Advertisement

2.5
E
NVIRONMENTAL
Temperature and humidity values experienced by the drive must be such that condensation does not occur on any
drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C).
Maximum wet bulb temperature is 82°F (28°C).
The recommended storage period:
Note
• 1 year under controlled conditions of 34°C 90%RH or less
• 90 days in uncontrolled storage conditions

2.5.1 Ambient Temperature

Operating
The drive meets the operating specifications over a 41°F to 140°F (5°C to 60°C) drive case temperature range with a
maximum temperature gradient of 36°F (20°C) per hour.
The maximum allowable drive case temperature is 60°C. See Figure 2.5.1 for HDA case temperature measurement
location
The MTBF specification for the drive assumes the operating environment is designed to maintain nominal case
temperature. The rated MTBF is based upon a sustained case temperature of 104°F (40°C). Occasional excursions in
operating temperature between the rated MTBF temperature and the maximum drive operating case temperature may
occur without impact to the rated MTBF. However, continual or sustained operation at case temperatures beyond the
rated MTBF temperature will degrade the drive MTBF and reduce product reliability.
Air flow may be required to achieve consistent nominal case temperature values. To confirm that the required cooling is
provided for the electronics and HDA, place the drive in its final mechanical configuration, and perform random write/
read operations. After the temperatures stabilize, measure the case temperature of the drive.
Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification
assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.
Note
Image is for reference only, may not represent actual drive
Seagate Kinetic HDD Product Manual, Rev. A
L
IMITS

Figure 1 Location of HDA Temperature Check Point