ASSEMBLY AND INSTALLATION
Installing
Az/EI
Cap Mount Onta Pole
Before installing az/el cap onto pole, installation mount
should be in place. loosen (4) hex nuts on pipe
clamp.
Install
az/el cap onto pole. Equally tighten
(4)
clamp bolts so that
cap is held stationary on pole, but can be swiveled w ith
slight
pressure.
Tighten approximately
2.7
N-m
(2
ft-Ib ).
Insert
(2)
MS set screws into threaded inserts in pipe clamp.
Do not tighten
.
Assembling Reflector Onto
Az/EI
Cap Mount
Clamp
Bolts
(4
Places)
Back View
MS Set
Screws
(2
Places)
Install four MS x
60
mm plow bolts into holes in reflector
face.
lift reflector and insert exposed portion of bolt into
holes
in az/el mounting
flange.
Secure reflector to az/el mount with
4
lock washers and hex nuts onto plow
bolts.
Tighten and torque to
15
N-m
(11
ft-Ib). Press fit
hole plugs in remaining four unused holes of the
reflector.
IMPORTANT:
Note orientation of feed leg mounting holes
in
reflector rim. Top of reflector does NOT have feed leg mounting
hole.
Front View of Reflector
_.
,
-
' ,
.
,
-'
.
.
--
..
MS
:
60mm
C
PIOW
.•
BOitS
.
(4 Places)
-
-
-
--.
\0~~ug,
(4 Places)
MS x
60
mm
Plow Bolts
(4 Places)
5
Rear View of Reflector
~~r---Az/EI
Installation Pole
lock Washer
(4 Places)
Cap
Mount

Hide quick links: