Then, another press on these two keys will unlock the keypad.
4.
Memory
Under the "Off" status of the unit, it is available to switch the memory mode by pressing the keys
"Mode" and "▲" simultaneously.
When "88" LED displays "ON", it indicates the memory function is activated; if "OF" is displayed,
it indicates that the memory function is deactivated. When the memory setting page comes out, it can
quit five seconds later or by pressing the "ON/OFF" key.
5.
Setting of the wired controller
The default status is that the unit is without the control of the wired controller.
Under the "Off' status of the unit, by pressing the keys "Mode' and "Speed" simultaneously, it is
available to set if the unit is with or without the control of the wired controller.
When "88" LED displays "E6" and the wired control is in normal status, it indicates the unit is the
control of the wired controller rather than the keys on the control panel and the remote controller.
When "88" LED is in the normal status and the wired controller displays "E6", it indicates the unit
is the control of the keys on the control panel and the remote controller instead of the wired controller.
6.
Setting of the master/slave unit
Under the "Off" status of the unit, it is available to switch the host and slave status of the unit by
pressing the key "Mode" for five seconds.
When "88" LED displays "HO", it indicates this indoor unit now is the host unit.
When "88" LED displays "CH", it is regarded as the slave unit as it has no valid host unit
When "88" LED displays "SL", it indicates this indoor unit now is the slave unit.
7.
Enquiry of the unit status, host or slave
Under the "Off" status of the unit, it is available to equity the unit status, host or slave, by pressing
the key 'Speed". "HO" indicates it is the host unit, while "CH" or SL" indicate it is the salve unit.
5.1.3 Introduction to the Display Function of the Air Conditioners
1.
SET: display the set temperature.
2.
TEMP: display the indoor ambient temperature.
3.
TURBO: when it lights up, it indicates the turbo function is already set.。
4.
SAVE: it indicates the energy conversation mode.
5.
SWING
: it shows the up/down swing status.
6.
SWING
: it shows the left/right swing status.
7.
BLOW: when it lights up, it indicates the blow function is already set.
8.
E-HEATER: When it lights up, it indicates the E-heater function is activated and the E-heater can
run under some certain conditions.
9.
TIMER: when it lights up, it indicates the timer function is already set.
10. AIR: when it lights up, it indicates the air function is already set.
11. SLEEP: when it lights up, it indicates the sleep function is already set.