Carrier 40RC003603 Owner's Manual
Carrier 40RC003603 Owner's Manual

Carrier 40RC003603 Owner's Manual

Carrier 40rc003603 central remote controller for 64 systems air conditioner

Advertisement

Quick Links

CENTRAL REMOTE CONTROLLER
FOR 64 SYSTEMS
FOR AIR CONDITIONER ACCESSORY PARTS
Model
40RC003603
Thank you for purchasing the Central Remote
Controller for Air Conditioner Accessory Parts.
• This Owner's Manual describes cautions on
using the Central Remote Controller for 64
systems.
• It is important to read this Owner's Manual
thoroughly for safe and correct usage.
• This Owner's Manual should be kept for other
users at place where anybody can read.
CONTENTS
Safety Precautions .............................................. 2
Maintenance ......................................................... 2
Features and Functions ..................................... 3
Entering to Zone .................................................. 7
Cancel of Zone Entering .................................... 8
Operation .............................................................. 9
Timer Operation ................................................. 14
Set Up Method of Operation Mode ................. 15
Adjustment of Air Direction ............................. 16
FILTER Sign ........................................................ 17
Check and Confirmation .................................. 18
External View ...................................................... 19
OWNER'S MANUAL
MONITOR
ZONE
SET
ALL
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
MONITOR/SET ALL/ZONE
ZONE
ZONE SET/ENTER SELECT
ON
CENTER
AUX. TYPE
STANDBY
UNIT
OFF
LOCKED
TIMER No.
FILTER
MODE
FAN
TEMP. CHECK
FAN ONLY
AUTO
1
COOL
HIGH
2
DRY
MED.
LOUVER
HEAT
LOW
AUTO
FIX
MANUAL
UNIT
ON CENTER/LOCKED
MODE
TEMP.
FILTER RESET
CHECK
FAN
LOUVER
OFF
TIMER ON
ON
°C

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 40RC003603

  • Page 1: Table Of Contents

    OWNER’S MANUAL CENTRAL REMOTE CONTROLLER FOR 64 SYSTEMS FOR AIR CONDITIONER ACCESSORY PARTS Model 40RC003603 Thank you for purchasing the Central Remote Controller for Air Conditioner Accessory Parts. • This Owner's Manual describes cautions on MONITOR ZONE CENTER AUX. TYPE...
  • Page 2: Safety Precautions

    Safety Precautions • Please read this section carefully before usage in the prescribed manner. The precautions given here deal with serious safety issues. It is , therefore, of the utmost importance that they are observed in full. • The meanings of safety-related symbols are as follows. WARNING This symbol is used to identify actions which, if carried out in an incorrect manner, could lead to serious personal injury or even death.
  • Page 3: Features And Functions

    Connecting a weekly timer (40RC004603) sold separately or a timer on the market, the central remote controller can also perform timer operation. Weekly timer 40RC004603, etc. System 1 System 2 System 64 (Unit No.1) (Unit No.2) (Unit No.64) Central remote controller Indoor units up to Max. 64 systems (Use of two controllers is possible.) 40RC003603...
  • Page 4: Names And Operation Of Each Part

    • Systems of the indoor units are shown below. (3) Max. 16 indoor units which are operated as a group by one or two remote controller(s) (1) Single indoor unit without remote controller Indoor unit Single Max. 16 units remote controller (2) Single indoor unit controlled by one or two remote controller(s) Max.
  • Page 5 Indication section Indication examples show all the contents for explanation. In practice, the selected contents are displayed. Last-push priority/Center/Locked indication Indicates the operation status of the remote controller ON/OFF indication at indoor unit side. Indicates that the air conditioner of which unit No.
  • Page 6 Operation section Select a desired operation by pushing each button. Last-push priority/Center/Locked button MODE button Selects Last-push priority/Center/Locked. Selects the desired operation mode. ON/OFF button Starts/Stops the air conditioner. FILTER RESET button Resets (Erases) “FILTER” ALL/ZONE/UNIT button indication. Selects that start/stop/every set up operations are CHECK button performed for all units, zone,...
  • Page 7: Entering To Zone

    Entering to Zone Multiple systems of the indoor units are set as a zone. Start/Stop control and every kind setting are available in each zone. At shipment from the factory, one unit as one zone is set in 64 zones each. (NOTE 1) If a unit is set to an incorrect zone, set the unit to the correct zone another time.
  • Page 8: Cancel Of Zone Entering

    Cancel of Zone Entering Cancel of zone entering for each unit [ZONE SET] Push “ZONE SET/ENTER” button while “MONI- TOR” is indicated. Indication changes to [ZONE SET]. ZONE UNIT Pushing “ZONE” button matches Zone No. to be canceled. “SET”, “ZONE”, “UNIT” indications and the Unit No.
  • Page 9: Operation

    Operation Setting to the operation mode (MODE, FAN, TEMP ., etc.), the operation handling mode (Last-push priority/CENTER/ LOCKED), timer link, and louver operation can be set for individual unit, for a zone, or for all units. Individual setting [Example] When Unit No. 1 to 17, 32, 33, 48, 49, 64 air conditioners are connected, start (or stop) Unit No.64 air condi- tioner.
  • Page 10 Collective setting in a zone All the indoor units entered in a zone can be started/stopped with the same set up contents. [Example] Start (or Stop) the Zone No.1 (Unit No. 1 to 5 are set.) air conditioner. Selection of MONITOR/SET Push “MONITOR/SET”...
  • Page 11 Individual setting in a zone An indoor unit entered in a zone can be started/stopped with the individual set-up contents. [Example] Start (or Stop) the Unit No.2 air conditioner in the Zone No. 1 (Units No. 1 to 5 are set.). Selection of MONITOR/SET Push “MONITOR/SET”...
  • Page 12 Collective setting All the connected indoor units can be started/stopped with the same set up contents. Selection of MONITOR/SET Push “MONITOR/SET” button to match to “SET”. “MONITOR” indication goes off and “SET” indication flashes. Selection of ALL/ZONE/UNIT Push “ALL/ZONE” button to match to “ALL”. CENTER UNIT TIMER...
  • Page 13: Start/Stop Operation For All/Zone

    Start/Stop Operation for ALL/ZONE Method of collective start/stop All the connected indoor units can be started/stopped with individual set-up contents. Check that “MONITOR” indication goes on. If “MONITOR” indication goes off, push “MONITOR/SET” button to match to “MONITOR”. MONITOR CENTER MODE TEMP .
  • Page 14: Timer Operation

    Timer Operation • For timer operation, a weekly timer (40RC004603) or a timer on the market is required. • You can start (ON timer) or stop (OFF timer) the operation of air conditioner at the desired time. • Setting of the timer operation is available in ALL, ZONE, or UNIT mode. [Example] A case in which the timer operation is set to ZONE No.
  • Page 15: Set Up Method Of Operation Mode

    Set Up Method of Operation Mode [Example] When Unit No. 1 to 17, 32, 33, 48, 49, 64 air conditioners are connected, start (or stop) Unit No. 64 with the desired set-up contents of the operation modes (MODE/FAN/TEMP ./LOUVER operation). Selection of MONITOR/SET Push “MONITOR/SET”...
  • Page 16: Adjustment Of Air Direction

    Adjustment of Air Direction • For details, refer to the Owner’s Manual attached to the indoor unit. To operate the discharge louver automatically Selection of MONITOR/SET Push “MONITOR/SET” button to match to “SET”. If the operation stops, push “ON” button. “ON” indication goes on. UNIT MODE TEMP .
  • Page 17: Filter Sign

    FILTER Sign In this central controller, “FILTER” indication notifies for each indoor unit of cleaning time of the air filter of the indoor unit. (Extended operation time has been already set up at shipment from the factory.) Selection of UNIT No. Pushing “UNIT”...
  • Page 18: Check And Confirmation

    Check and Confirmation When “MODE” findication goes off The system stops because the protective device worked. When a trouble was detected in operation Be sure to read the Owner’s Manual attached to the indoor unit before asking repair/service, and then contact the dealer which you purchased the air conditioner.
  • Page 19: External View

    TUNE Specifications Power source AC 100V to 240V, 50/60Hz Power consumption Max. 2W Use ambient temp./Humidity 0 to 40°C / up to 80% (However, no dewing) Dimension 180 x 120 x 65.6 (Width x Height x Depth) Mass 420g External View 65.6 15.6 •...