30
9.0 OpErATION
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal
Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
Assure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the fireplace will emit an odor for a few
hours. This is a normal temporary condition caused by the "burn-in" of paints and lubricants used in the manufacturing process and will not
occur again. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight
odor for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate
the room.
A. This fireplace is equipped with an ignition device which automatically lights he pilot. Do not try to light by hand.
B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will
settle on the floor.
C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a
qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace
and replace any part of the control system and any gas control which has been under water.
● Turn off all gas to the fireplace.
● Open windows.
● Do not try to light any appliance.
● Do not touch any electric switch; do not use any phone in your building.
1. Stop! Read the above safety information on this label.
2. Turn remote wall switch to off position.
3. Turn off all electrical power to the fireplace and remove batteries.
4. This fireplace is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
5. Turn manual shutoff valve clockwise to off.
6. Open the glass door.
7. Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" in the
above safety information on this label. If you don't smell gas go to the next step.
8. Close the glass door.
9. Turn manual shutoff valve counter-clockwise to on.
10. Turn on all electrical power to the fireplace and re-install batteries.
11. Turn on remote wall switch to on position.
12. If fireplace will not operate, follow instructions "TO TURN OFF GAS" and call your
service technician or gas supplier.
1. Turn off remote wall switch to the fireplace.
2. Turn off all electrical power to the fireplace if service is to be preformed.
3. Turn manual shutoff valve clockwise to off. Do no force.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified
service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable vapors and liquids.
The flow of combustion and ventilation air must not be obstructed.
● In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies.
● Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at
least once a year.
● Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.
● Check to see that the pilot flame is large enough to engulf the sensor on one leg and reaches toward the burner on the other leg.
TP - OPERATION DExEN EI
● Replace the cleaned logs.
● Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second
W415-0547 / D / 11.14.08
total light-up period is satisfactory. If ignition takes longer, consult your Authorized dealer / distributor.
● Check that the door gasketing is not broken or missing. Replace if necessary.
injury or loss of life.

FOR YOUR SAFETY READ BEFORE LIGHTING:

WHAT TO DO IF YOU SMELL GAS:

LIGHTING INSTRUCTIONS:

TO TURN OFF GAS
MAINTENANCE
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE.
WARNING
!
● Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
● If you cannot reach your gas supplier, call the fire
department.
WARNING
!
Manual Shut-off
Valve Shown in
"OFF" position
.

Hide quick links: