22
4.0 mINImum CLEArANCE TO COmBuSTIBLES
Minimum clearance to combustibles must be maintained or a serious fire hazard could result.
Framing or finishing material closer than the minimums listed must be constructed entirely of
As long as clearance to combustibles is kept within the required distances, the most desirable and beneficial
location for a Napoleon® stove is in the centre of a building, thereby allowing the most efficient use of the heat
created. The location of windows, doors and the traffic flow in the room where the stove is to be located should
be considered. If possible, you should choose a location where the vent will pass through the house without
cutting a floor or roof joist.
fIGure 4.1a
a.
4"
Stove should not be installed directly on carpeting.
To ceiling from stove top
Horizontal vent
Sides and bottom
Top
vertical vent
All sides
*At a distance of 2" from the wall, installation or service to the blower may not be practical. A minimum of 5" will
be required in order to install the blower. If less than 5" clearance is maintained between the back of the stove
and the back wall, it will be necessary to disconnect the venting and gas pipe to move the stove out for installa-
tion or service of the blower.
W415-0547 / D / 11.14.08
non-combustible materials (i.e. steel studs, cement board, etc.).
Never obstruct the front opening of the heater.
b.
2"*
c.
2"
48"
1"
2"
1"
WARNING
!
fIGure 4.1b
WARNING
!
!
fIGure 4.1c