2.8
vErTICAL ThrOugh ExISTINg ChImNEy
This appliance is designed to be attached to a 3" co-linear aluminum flex
vent system running the full length of a masonry chimney.
The flex liner accommodates any contours of a masonry chimney,
however, it is necessary to keep the flexible liner as straight as possible.
The inlet air collar of the termination cap must be connected to the air
intake pipe.
Use Simpson Duravent Chimney Liner Termination Kit - 923GK
(base plate and Co-Linear to Co-Axial Adaptor. Follow
manufacturers (Simpson Dura-Vent) installation instructions.
When installing the unit to this system, Duravent vent
components must be used. you must start with a Duravent
adaptor, GDS924N, directly off the unit. The GDS924N is only
available at your Napoleon® dealer.
AIR
INTAKE
fIGure 2.8
15
EXHAUST
FLUE
FLEX
LINER
40 FEET
MAX.
3 FEET
MIN.
W415-0547 / D / 11.14.08