Configuring Fabric-Required Mode - Cisco 6500 Series Software Configuration Manual

Hide thumbs Also See for 6500 Series:
Table of Contents

Advertisement

Configuring the Switch Fabric Module
When configuring the switching mode, note the following syntax information:
When you enter the no fabric switching-mode allow bus-mode command, power is removed from any
Caution
nonfabric-enabled modules installed in the switch.

Configuring Fabric-Required Mode

Note
The commands in this section are supported only with Release 12.1(11b)E and later.
To configure fabric-required mode, which prevents all switching modules from operating unless there is
a Switch Fabric Module installed, perform this task:
Command
Router(config)# fabric required
Router(config)# no fabric required
If you enter the fabric required command on a switch that does not have a Switch Fabric Module
Caution
installed, all modules except the supervisor engine turn off.
When configuring fabric-required mode, note the following syntax information:
Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide—Release 12.1 E
37-4
To allow use of nonfabric-enabled modules or to allow fabric-enabled modules to use bus mode,
enter the fabric switching-mode allow bus-mode command.
To prevent use of nonfabric-enabled modules or to prevent fabric-enabled modules from using bus
mode, enter the no fabric switching-mode allow bus-mode command.
To allow fabric-enabled modules to use truncated mode, enter the fabric switching-mode allow
truncated command.
To prevent fabric-enabled modules from using truncated mode, enter the no fabric switching-mode
allow truncated command.
To configure how many fabric-enabled modules must be installed before they use truncated mode
instead of bus mode, enter the fabric switching-mode allow truncated threshold number command.
To return to the default truncated-mode threshold, enter the no fabric switching-mode allow
truncated threshold command.
If you boot the switch with fabric-required mode configured but without a Switch Fabric Module
installed, only the supervisor engine receives power; no switching modules power up.
When the switch is operating with fabric-required mode configured and a Switch Fabric Module
installed, if you remove the switch fabric module or if it fails, the switch removes power from all
switching modules; only the supervisor engine remains active.
When the switch is operating with fabric-required mode configured and with redundant Switch
Fabric Modules installed, if you remove both switch fabric modules or if both fail, the switch
removes power from all switching modules; only the supervisor engine remains active.
Chapter 37
Purpose
Configures fabric-required mode, which prevents switching
modules from operating without a switch-fabric module.
Clears fabric-required mode.
Configuring the Switch Fabric Module
78-14099-04

Advertisement

Table of Contents
loading

Table of Contents