DIAGNOSIS & TROUBLESHOOTING
IMPORTANT SETUP INFORMATION
Using a Palm
Handheld
The electronic control is factory preset to ac-
cept commands from a Palm
equipped with the appropriate Whirlpool Man-
agement Software. If a handheld will not be
used, the handheld functionality must be dis-
abled as part of the control set up. Failure to
disable handheld functionality may result in un-
authorized machine access. For details, see the
OWNER SETTINGS table "P ACc," on page 6-5.
Money Acceptors
This electronic control can use a coinslide or
coindrop (single or dual) and/or a SMART Card
money acceptor, which are available from in-
dependent suppliers of these devices.
The electronic control is used on many differ-
ent models, including metercase models. On
this machine, the electronic control is factory
preset to accept input only from a coinslide
device.
To instruct the control to accept inputs from
other devices or to disable input from a coinslide,
see the OWNER SETTINGS table (droP, SLidE,
CArd,) on page 6-4. These settings can be also
made using a Palm
priate Whirlpool Management Software.
Device Connections:
Refer to the installation instructions from the
supplier of each device. Refer to the wiring
diagram for this product.
• Coinslide connection is made via the wire
harness provided in the metercase.
• Coindrop connection to a single or dual
coindrop is made via the wire harness
provided with the device, plugged into the
electronic control at P-10 COIN 1, and P-12
COIN 2.

DIAGNOSIS

Washers With Metercase

Models CAE2761K & CAE2762K
handheld
handheld with the appro-
• Connection to a SMART Card device is
provided with the device plugged into the
electronic control at P-11 AUX.
ACCESS MODE
Using a Palm
Handheld With Software
1. Use Service Routine software.
2. To minimize possible infrared (IR) interfer-
ence from other sources, hold the handheld
at a 90° angle no more than three inches
from the control panel, pointed directly at
the right side of the vend-price LED display.
3. After selecting the command, the HOT tem-
perature LED begins blinking to confirm
command was received. The machine's
lifetime cycle count now shows in the dis-
play.
If a Palm
Handheld With Software
Is Not Available
1. Unlock and remove the service access
door on top of the metercase.
2. Push and release the rocker switch, lo-
cated inside the metercase, or push and
release the Service Switch S1 on the
ADVANTECH
3. The HOT temperature LED begins blinking
to confirm that the switch was pushed. The
machine's lifetime cycle count now shows
on the display.
NOTE: The display automatically returns to the
vend-price after 1 minute of inactivity.
SERVICE ROUTINE
1. Perform all steps under "Access Mode."
2. Push and release keypad position 2
(WARM). The WARM LED starts blinking to
confirm the keypad push.
3. Refer to new keypad functions in the table
on page 6-2.
NOTE: Service Routine turns itself off after
5 minutes of inactivity.
6-1