INSTALLER'S GUIDE
8. Connect the female polarized plug (disconnected
in item 2 from the wire bundle next to the
knockouts) to the male polarized plug on the
bottom of the heater control box
9. Refer to the heater minimum airflow chart on the
air handler rating nameplate for the appropri-
ate minimum blower speed tap to be used with
the approved heater installed.
10. For heaters with self contained disconnect, an
opening in the blower access panel is provided so
that the disconnect may be operated without
Heater
Model No.
BAYHTR1405 +++
BAYHTR1408 +++
BAYHTR1410 +++
BAYHTR3410 000
BAYHTR1415 BRK
BAYHTR3415 000
BAYHTR1419 BRK
BAYHTR1425 BRK
+++ = 000, BRK, PDC
000 = pigtails, BRK = contains Circuit Breakers, PDC = contains Pull Disconnect
Page 2
BAYHTR -- HEATER DATA
Number
of
Phase
Circuits
KW BTUH
1
1
4.80
1
1
7.68
1
1
9.60
1
3
9.60
2
1
15.36
1
3
15.36
2
1
19.20
3
1
24.96
removal of the blower access panel. Remove the
metal cover from the circuit breaker opening in
the air handler access panel and discard, cut out
the fiberglass insulation only in the areas where
the disconnect will extend through the opening.
11. Replace all panels removed during the heater
installation.
240 VOLT
Heater
Capacity
Amps per
Circuit
16400
20
26200
32
32800
40
32800
34.6
52400
40/24
52400
38.2
65500
32/48
85200
44/40/20
208 VOLT
Heater
Capacity
Amps per
Circuit
KW BTUH
3.60
12300
5.76
19700
7.20
24600
7.20
24600
11.53
39300
34.6/20.8
11.53
39300
14.42
49200
27.7/41.6
18.73
63900
38.1/34.6/17.3
18-HB13D7-2
17.3
27.7
34.6
30
33.1