INSTALLER'S GUIDE

Section 2. General Information

This electric heater accessory is designed to provide
power directly to the air handler from the accessory
heater's power supply, eliminating the need for addi-
tional circuits. The power and control wiring each use
a single wire harness to connect the heater and the air
handler.
1. Check the unit heater label to confirm that the selected
heater is approved for use with the air handler in the in-
stalled configuration. For some heaters, a corresponding
secondary nameplate label is included. Place the label
within the heater data table on the air handler nameplate.
2. Check the components received for damage. Report any
defects or shortages to the transportation company im-
mediately.
3.
Be sure the power supply matches the listing shown on
the heater nameplate.

Section 3. Heater Assembly Labeled

Retainer Tab and
Screw
- In document pack
Filler Plate
Electric Heat
Control Platform
Edge Guard
- In document
Electric Heat
pack
Control -
Communicating
Seal Plate
(Breaker models only)
- In document pack
Page 2
Base Plate
Cyclic Thermal
Limit Switch
Heater Element
Terminations
Ground Lug
(LG heater has terminal lug)
Breaker Bracket
(LG heater terminal bracket differs)
Circuit Breaker
(Breaker models only)
Heater Rack
Nameplate
Width Adjustment Brackets
Heater Baffle
Non-Cyclic Thermal
Limit Switch
Retainer Tab and
Screw
- In document pack
Filler Plate
Wiring diagram not shown
Parts may vary by model. Items shown
are for illustrative purposes only.

Hide quick links:

Advertisement

loading