7510
1X 500-sheet drawer (1TM)—sensor (tray 2 feed-out) removal
1. Open the 1TM left door assembly.
2. Remove the two screws securing bracket (A) to the machine.
3. Remove the bracket (A).
4. Disconnect the connector from the sensor (tray 2 feed-out) (B).
5. Release the hooks securing the sensor (tray 2 feed-out) (B) to the bracket (B).
6. Remove the sensor (tray 2 feed-out) (B).
4-244
Service Manual
Connector
Hook
A
B
Actuator
Previous
Next