Security Settings - AMX MVP-7500 Operation/Reference Manual

Mvp-7500/8400 modero viewpoint wireless touch panels mvp-bp power pack nxa-cfsp compact flash card
Hide thumbs Also See for MVP-7500:
Table of Contents

Advertisement

Security Settings

The Security button on the Protected Setup page has three settings: Standard Security, Secure, and
DoD. Each setting has different features for touch panel security:
Security Profile Features
Standard Security: • Factory default, shipped in this configuration.
Secure:
DOD:
Toggling between these three immediately and automatically resets the existing password to the default
password for that setting. With an unsecured panel using the Standard Security setting, the default
password is 1988. With panels using either the Secure or the DoD settings, the default password is
Amx1234! (paying attention to the case of the letters). Entering the existing password will not work and
the default will need to be entered at this point will allow access to the Protected Settings page and allow
resetting of the password to a new one.
If the Security button setting is changed in any way, even if it is toggled back to its
original setting, the password is automatically reset to the default for the chosen
setting. You MUST use the new default of 1988 (Standard Security) or Amx1234!
(Secure or DoD) to re-enter the Protected Settings page.
MVP Modero ViewPoint Touch Panels
• Administrator and NetLinx user accounts have a default password of "password".
• Telnet, HTTP, HTTPS, and SSH are all enabled and require no authentication.
• Program terminal requires no authentication.
• ICSP communication protocol between devices: encryption and authentication are
disabled.
• FTP is enabled.
• Minimum password requirement is 4 characters.
• Must be configured from the program terminal.
• HTTP, Telnet, and FTP are disabled.
• SSH, HTTPS, and program terminal require authentication by an authorized user.
• SSH, HTTPS, and program terminal session timeouts are enabled.
• ICSP communication protocol between devices: encryption and authentication are
enabled.
• Minimum password requirement is 8 characters with at least 1 numeric character.
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful login attempts, login lockout is enabled for 15
minutes.
• Login and logout audit logging is enabled.
• Must be configured from the program terminal.
• HTTP, Telnet, and FTP are disabled.
• SSH, HTTPS, and program terminal require authentication by an authorized user.
• SSH, HTTPS, and prgogram terminal session timeouts are enabled.
• ICSP communication protocol between devices: encryption and authentication are
enabled.
• Minimum password requirement is 8 characters with at least 1 numeric character, one
uppercase character, one lowercase character, and one special character, with no
duplicate adjacent characters.
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful login attempts, login lockout is enabled for 15
minutes.
• Login and logout audit logging is enabled.
• DoD session banner is enabled.
Setup Pages
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvp-8400

Table of Contents