MAINTENANCE AND TROUBLESHOOTING

Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the con-
sole and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in.
If the console does not display your heart rate when
you hold the handgrip pulse sensor, or if the displayed
heart rate appears to be too high or too low, see step
5 on page 16.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, hold
down the Calorie Workouts button for about 5 seconds
until the display on the console changes.
Press the Calorie Workouts button once. The ramp
calibration instructions will appear in the display. Press
the Quick Ramp increase or decrease button to cali-
brate the ramp. The ramp will move upward and
downward as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Calorie Workouts button three times
to return to the manual mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch, you must first remove the
screws attaching the right shield (see the instructions
below).
Remove the indicated #8 x 3/4" Screws (78) from the
Right and Left Shields (38, 39). Then, gently pull the
Right Shield away from the frame.
38
39
78
Locate the Reed Switch (47). Loosen, but do not
remove, the #8 x 1/2" Screw (91).
91
134
47
Next, rotate the Large Pulley (17) until a Magnet (134)
is aligned with the Reed Switch (47). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the #8 x 1/2" Screw (91).
Rotate the Large Pulley (17) for a moment. Repeat
these actions until the console displays correct feed-
back.
When the reed switch is correctly adjusted, reattach
the right shield.