Lenovo THINKSERVER RS210 Hardware Maintenance Manual page 51

Lenovo server user manual
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing, RS210 Types 6531, 6532, 6533, and 6534," on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Redundancy Bckup Mem Status has
been reduced.
IMM Network Initialization
Complete.
Certificate Authority %1 has
detected a %2 Certificate Error.
(%1 = IBM_CertificateAuthority.
CADistinguishedName;
%2 = CIM_PublicKeyCertificate.
ElementName)
Ethernet Data Rate modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.Speed;
%2 = CIM_EthernetPort.Speed;
%3 = user ID)
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.FullDuplex;
%2 = CIM_EthernetPort.FullDuplex;
%3 = user ID)
Ethernet MTU setting modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.
ActiveMaximumTransmissionUnit;
%2 = CIM_EthernetPort.
ActiveMaximumTransmissionUnit;
%3 = user ID)
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.
NetworkAddresses;
%2 = CIM_EthernetPort.
NetworkAddresses;
%3 = user ID)
Ethernet interface %1 by user %2.
(%1 =
CIM_EthernetPort.EnabledState;
%2 = user ID)
Error
Redundancy has been lost
and is insufficient to
continue operation.
Info
An IMM network has
completed initialization.
Error
A problem has occurred
with the SSL Server, SSL
Client, or SSL Trusted CA
certificate that has been
imported into the IMM. The
imported certificate must
contain a public key that
corresponds to the key pair
that was previously
generated by the Generate a
New Key and Certificate
Signing Request link.
Info
A user has modified the
Ethernet port data rate.
Info
A user has modified the
Ethernet port duplex setting.
Info
A user has modified the
Ethernet port MTU setting.
Info
A user has modified the
Ethernet port MAC address
setting.
Info
A user has enabled or
disabled the Ethernet
interface.
1. Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2. Re-enable mirroring in the
Setup utility.
No action; information only.
1. Make sure that the certificate
that you are importing is
correct.
2. Try importing the certificate
again.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
Chapter 4. Diagnostics
43

Advertisement

Table of Contents
loading

Table of Contents