8

Commissioning

.02
Check the machine, especially the electric leads, for any damage.
Clean the machine thoroughly, also see Chapter 11 Care and maintenance.
Connect the machine to the electricity supply and have specialists check, whether the
machine can be operated with the available mains voltage and whether it is connected
properly.
1
Fig. 8 - 05
The machine must only be commissioned by qualified personnel. All relevant
safety regulations must be observed.
If there are any deviations, do not operate the machine under any
circumstances.
The machine may only be connected to an earthed socket!
Installation and commissioning
Attach the compressed air tube to
coupling 1. The gauge should display a
pressure of 6 bar. If this is not the case,
adjust it to this level, see Chapter 11.02
Checking / adjusting the air pressure.
The air must be completely free
of oil and dry. The compressed
air quality influences the service
life of the heating cartridge in
the air heater. If the air is very
damp, a compressed air low-
temperature drier with
preliminary filter and secondary
microfilter must be installed in
front of the sealing machine.