CABLES - IMPORTANT
If you want to use an extension cable when operating
your product, only the following cable dimensions should
be used.
-
1.0 mm
: max length 40 m
2
-
1.5 mm
: max length 60 m
2
-
2.5mm
: max length 100 m
2
Minimum rating :
1.00mm
2
size cable, 10 amps 250 volts AC.
• YOUR PRODUCT IS SUPPLIED WITH CABLE
WIRED DIRECTLY INTO THE PRODUCT.
1. If the supply cord is damaged, it must be replaced
by your local Husqvarna UK Ltd. Approved Service
Centre or similarly qualified persons in order to avoid
a hazard.
2.Flymo Extension Cables are available from your
local Husqvarna UK Ltd. Approved Service Centre.
3.Do not wire an extension cable directly to your product
yourself. Please contact your local Husqvarna UK Ltd.
Approved Service Centre for further information on the
connectors and kits available.
4.Only use extension cables specifically designed for
outdoor use and which conform to one of the following
specifications: Ordinary rubber (60245 IEC 53),
Ordinary PVC (60227 IEC 53) or Ordinary PCP (60245
IEC 57)
CONNECTORS - IMPORTANT
• Flymo connectors are suitable for use with 2 core
cable only. Under no circumstances should these
connectors be used for earthed products.
• All Flymo connectors and cables are of splashproof
construction. They are not waterproof and must not
be left outside permanently nor should they be
submerged or immersed in water. Do not let cable lay
A
B
C
D

Assembly Instructions

or trail through pools of water or splashed with water
from hose pipes.
MAINS PLUG REPLACEMENT - IMPORTANT
• If the plug supplied is cut off it should be destroyed.
There is an electric shock hazard if a cut off plug is
inserted into a 13 amp socket.
1. No earth required. Flymo products are double
insulated to EN60335 and under no circumstances
should an earth be connected to any part of the
product.
2. Ensure the mains voltage suits your product
3. IMPORTANT!
The wires in the mains lead are coloured in
accordance with the following code:
BLUE - NEUTRAL
The wire which is coloured BLUE must be connected
to the Terminal which is marked with the letter 'N' or
coloured BLACK. The wire which is coloured BROWN
must be connected to the Terminal which is marked
with the letter 'L' or coloured RED.
4. It is important that the outer sheath is clamped
correctly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only protect
the electrical equipment and are not a safeguard
against electrocution.
If your product is hard wired i.e. non-detachable mains
electric cable, a conversion kit and extension cable is
available from all Husqvarna Outdoor Products
Approved Service Centres which can be found in your
local Yellow Pages.
Assembly Instructions
Wheel Assembly (A)
1. Insert the wheel bolt into the threaded hole.
2. Fully tighten the bolts using a screwdriver.
Assembly of Lower Handles to Deck
1. Place the hole in the lower handle over the end of the
bolt (B)
2. Place the wing knob onto the end of the bolt and firmly
tighten. (B)
3. Repeat on the other side.
Assembly of Upper Handles to Lower Handles.
1. Ensure the upper handle is located correctly with the
lock-off button on the switchbox uppermost.
2. Ensure the upper handle and the lower handle are
aligned correctly.(C)
3. Fit the bolts, washers and wing knobs.(C)
4. Fit the cable to the handles with the clips provided.
Make sure the cable is not trapped between the upper
and lower handles.
Height Adjust Handle Assembly
1. Insert the height adjust arm into the slot at the base of
the height adjust handle (D)
2. Firmly push the handle on to the arm.
3. The handle will automatically lock on to the arm.
BROWN - LIVE