Sony MVC-FD97 Service Manual page 85

Digital still camera
Hide thumbs Also See for MVC-FD97:
Table of Contents

Advertisement

3. Flange Back Adjustment
(Using the flange back adjustment chart and a subject
more than 500 m away)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
3-1. Flange Back Adjustment (1)
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
3) Check that the data on page: F, address: 14 to 25 are initial
value (See table below).
Address
Data
Address
14
12
1D
15
A8
1E
16
38
17
08
18
17
19
67
1A
00
1B
00
1C
00
CAMERA
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Check operation on the LCD
screen
F
14 to 25
Data
00
41
1F
00
20
20
21
20
22
20
23
44
24
0A
25
00
Adjusting method:
Order Page Address Data
1
0
01
2
5
F1
3
D
63
4
5
6
01
6
6
01
7
6
02
Note 2: The adjustment data will be automatically input to
page: F, address: 14 to 25.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
5
F1
3
D
63
4
5
0
01
6
5-17
Procedure
01
FF
40
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
13
Press PAUSE button.
15
Press PAUSE button. (Note 2)
Check the data changes to "01".
Procedure
00
Press PAUSE button.
00
00
Press PAUSE button.
Release the data setting
performed at step 4.
(Refer to page 5-14)
00
Perform"Flange Back Adjust-
ment (2)".

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents