18. CCD Black Defect Compensation

Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2: Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
1
0
01
01
2
5
F1
FF
3
D
63
40
4
5
F
DF
6
F
DF
4C
7
6
2C
01
8
6
90
00
9
6
91
03
10
6
92
00
11
6
93
00
12
6
6C
01
13
6
01
79
14
6
30
01
15
16
6
01
8D
17
6
02
18
6
55
19
6
01
00
20
F
DF
5A
21
6
01
89
22
6
02
23
6
55
Note 3: The adjustment data will be automatically input to page:
7, address: 60 to 87.
CAMERA
Clear chart
(25 cm from the front of lens)
Displayed data of page: 6,
address: 55
Adjusting remote commander
7
60 to 87
Procedure
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Note down the data.
Press PAUSE button.
Press PAUSE button.
Wait for 4 seconds.
Press PAUSE button. (Note 3)
Check the data changes to "01".
Check the data.
00 to 0A : Normal
0B to FF : Defective
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Check the data changes to "01".
Check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustment:
Order Page Address Data
1
F
DF
2
6
01
3
6
2C
4
6
30
5
6
6C
6
6
91
7
5
F1
8
D
63
9
10
0
01
5-32
Procedure
Set data noted down at step
5, and press PAUSE button.
00
Press PAUSE button.
00
00
00
00
00
00
Press PAUSE button.
Release the data setting
performed at step 4.
(Refer to page 5-14)
00