Resetting The Usage Counter - Fujitsu FI-6010N Operator's Manual

Hide thumbs Also See for FI-6010N:
Table of Contents

Advertisement

Consumables
Color
PAD ASSY
Green
Orange
Red
PICK ROLLER
Green
Orange
Red

■ Resetting the Usage Counter

After part replacement, the usage counter can be reset to return the part status to normal.
For more details about replacing consumable parts, refer to
1. Select the [Device Status] tab on the top menu.
2. Select the [Usage Status] tab on the left side menu.
The "Usage Status" screen appears.
3. Press the [Clear] button for the part replaced.
The counter reset confirmation screen appears.
4. Press the [Yes] button.
The counter value is reset to "0", and the "Status" field turns green again.
4.8 Using the Device Status Menus
Status
Total throughput: 0 to 44,999
sheets
Total throughput: 45,000 to
49,999 sheets
Total throughput: Over
50,000 sheets
Total throughput: 0 to 94,999
sheets
Total throughput: 95,000 to
99,999 sheets
Total throughput: Over
100,000 sheets
fi-6010N Network Scanner Operator's Guide
Action
No action required.
Pad assy needs to be replaced
soon. Obtain a replacement
part.
Pad assy has passed its rated
lifetime and needs to be
replaced.
No action required.
Pick roller needs to be
replaced soon. Obtain a
replacement part.
Pick roller has passed its rated
lifetime and needs to be
replaced.
"7.6 Replacing Parts" (page
4
427).
153