Clearances to Combustibles

Minimum clearances to combustible materials in inches
(millimeters):
Parallel Installation
4-/"
(6mm)
Min.
-/"
(38mm)
Min.
Figure 3
Corner Installation
4-/"
(4mm)
Min.
Figure 4
Floor Protection
A noncombustible hearth pad is not required. This stove
may be installed on a combustible surface. Also, the floor
beneath the stove must be stable, level, hard and strong
enough to support the stove without a tipping hazard.
8
4" (0mm)
90°
0-/"
(67mm)
Min.
(4mm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Alcove dimensions
The minimum width between the alcove side walls is 48"
(1219mm). The minimum height of the alcove is 69" (753mm)
and the maximum depth is 48" (1219mm).
69"
(753mm)
Min.
(9mm)
Figure 5
Pipe Clearances
All installations using a vertical termination cap must
maintain one inch clearance between the direct vent pipe
4-/"
and combustibles. For horizontal runs of pipe, one inch of
clearance to combustibles on the sides and bottom and two
Min.
inches on the top of the pipe is required. See Page 16 for
allowable pipe configurations.
Alcove Dimensions
48"
(9mm)
Max.
48"
Min.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epic40

Table of Contents