Vent Parts List; Horizontal Vent Installation - Lennox Hearth Products EPIC33 Installation And Operation Manual

Direct-vent gas stove elite series
Table of Contents

Advertisement

Vent Parts List

Direct vent pipe Security™ Secure Vent™ * may be used
with the Epic™ gas stove. Please see the lists below to verify
the components available from each direct vent pipe manu-
facturer. Snorkel terminations are available for applications
which may require vertical rise on the building exterior. The
components listed below come in a galvanized finish. Most
of the components are also available in a painted black fin-
ish. Add a "B" to the end of the part number when ordering
if a black part is desired.
Security™ Secure Vent 6-5/8"x 4" Pipe
Part Number
Description
SV4LC
6" Pipe Length
SV4L12
12" Pipe Length
SV4L24
24" Pipe Length
SV4L36
36" Pipe Length
SV4L48
48" Pipe Length
SV4LA
6" Pipe, Adjustable
SV4LA12
12" Pipe, Adjustable
SV4FA
Flashing, 1/12 to 6/12 Roof Pitch
SV4FB
Flashing, 7/12 to 12/12 Roof Pitch
SV4RSM
Wall Radiation Shield
SV4E46
45º Elbow
SV4E90
90º Elbow
SV4VS
Vinyl Shield Protector
SV4FC
Storm Collar
SV4CGV
Vertical Termination Cap
SV4BF
Firestop
SV4CHC
Horizontal Termination Cap
SV4STC36
Snorkel Termination Cap (36")
SV4STC14
Snorkel Termination Cap (14")
SV4BM
Wall Band
Simpson Dura-Vent GS 6-5/8"x 4" Pipe
Part Number
Description
908
6" Pipe Length
907
9" Pipe Length
906
12" Pipe Length
904
24" Pipe Length
903
36" Pipe Length
902
48" Pipe Length
911
11" to 14-5/8" Pipe, Adjustable
942
Wall Thimble
940
Rnd Support Box/Wall Thimble Cover
941
Cathedral Ceiling Support Box
943
Flashing, 0/12 to 6/12 Roof Pitch
943S
Flashing, 7/12 to 12/12 Roof Pitch
945
45º Elbow
990
90º Elbow
950
Vinyl Siding Standoff
953
Storm Collar
963
Ceiling Firestop
988
Wall Strap
981
Snorkel Termination (36")
982
Snorkel Termination (14")
984
Horizontal Termination Cap
985
Horizontal Termination Cap (High Wind)
980
Vertical Termination Cap
991
Vertical Termination Cap (High Wind)
4

Horizontal Vent Installation

Venting terminals may not be recessed into a wall or
siding.
1. Set the unit in the desired location. Check whether or
not wall studs are in the way when the venting system is
attached. If wall studs are in the way, you may want to
adjust the location of the unit.
2. All horizontally terminated vent installations may only use
6-5/8"x 4" Security™ Secure Vent pipe*.
3. Assemble the desired combination of pipe and elbow(s)
to the appliance adapter with pipe seams facing down.
Offsetting the pipe seams as double seams in one place
will cause the outer pipe to take an oval shape.
4. When this pipe passes through a wall, a wall thimble
- Simpson #942 or Security™ #SV4RSM - is required.
The hole in the wall for the wall thimble should be 9-1/4"x
10-1/4". If the wall being penetrated is constructed of non-
combustible material (i.e. masonry block or concrete), a
7" diameter hole is acceptable and a wall thimble is not
required.
5. Horizontal runs of vent pipe must be supported every 3
feet. Wall straps - Simpson #988 or Security™ #SV4BM
- are available for this purpose.
6. If the vent passes through a ceiling or floor, a firestop
- Simpson #963 or Security™ #SV4BF - is required.
7. Also note that venting terminals shall not be recessed
into a wall or siding. If installing the termination cap on
a wall covered with vinyl siding, a vinyl siding standoff
- Simpson #950 or Security™ #SV4VS - or furring strips
must be used to ensure that the termination cap is not
recessed into the siding.
8. The horizontal run of vent should have a 1/4" (6mm)
rise for every 12" of run toward the termination. Never
allow the vent to run downward. This could cause high
temperatures and may present the possibility of a fire.
9. The location of the horizontal vent termination on an ex-
terior wall must meet all local and national building codes
and must not be blocked or obstructed. For allowable
external vent termination locations see Page 17.
10. A llowable clearances from the vent pipe to combustible
materials must be maintained. See Page 8 for these clear-
ances.
11. D o not locate the termination cap where it may be blocked
by shrubbery or snow.
* Other approved chimney brand is Simpson Dura-Vent DV-GS.