SPECIFICATIONS - Model T300P Series
Flue Size
Width, Overall
Depth, Overall
Height
Floor to Rear
Flue Center
Facing Back of Unit,
Outside Edge of Left Leg
To Center of Rear
Flue Outlet
Floor to Rear
Outside Air Inlet
Facing Back of Unit
Outside Edge of Left Leg
To Center of Air Inlet
Floor Protection
Requirements
Standard Features
Hopper Capacity
Burn time
Fuse, Control Board
Fuse, Igniter
Heat Input (Max.)
Overall Efficiency
Emissions
Ship Weight
Room Air Blower
Auger Motor
Exhaust Blower
Note: Dimensions shown are approximations only (+/- ¼")
3" / 76mm Rear
28 3/4" / 730 mm
26 1/2" / 660 mm
28 3/4" / 730 mm
8 3/4" / 222 mm
10 1/2" / 267 mm
10" / 254 mm
17 1/2" / 445 mm
+
Front and Sides: 6"/152mm
Back: Up to 6" / 152mm
Fastfire Self Igniter
Wall Thermostat
(wire included)
50 lbs.
♦ 14-34 hours
5 amp, 25 volt, 3AG*
6 amp, 125 volt*
♦ 13,000-32,000 BTU / hr
85%
♦ 0.43 gram / hr (varies w/
size and type of fuel)
EPA exempt
363 lbs.
150 CFM; 1.5 amps,
2175 rpm
1 RPM; .4 amps
95 CFM: 1.0 amps,
2880 rpm
8 3/4"
10 1/2"
17 1/2"
Face of door
opening to
stove back
+
Non-combustible thermal rated floor protection must
be used when installed on carpet (see Floor Protec-
tion, page 5). When installed at clearances less
than 6", the floor protector is only required to ex-
tend to the wall.
♦ Fuel delivery and burn times will vary depending
on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb.
* Fuses are rated as fast blow.
Page 26
BACK VIEW
28 3/4"
10 "
SIDE VIEW
26 1/2"
23"
28 3/4"

Hide quick links: