Brick Panel And Log Set Installation - Lennox Hearth Products C42 Installation And Operation Manual

Direct-vent gas fireplace
Table of Contents

Advertisement

Brick Panel and Log Set Installation

Brick Panel
The brick panels are extremely fragile so handle them with care.
1. Remove brick panels from box and wrapping.
2. The long rectangular panel goes in the rear of the firebox - the thin layer
of bricks should be down. The panel rests on three metal tabs protruding
from the rear of the firebox about 3" above the firebox floor.
3. On the side panels, the rounded edge goes to the front. Install the side
panels by sliding them along the side of the firebox into retainers at
the top and bottom.
Figure 25
Log Set
Log Installation Instructions
If logs are not installed according to the log installation instructions,
flame impingement and improper combustion could occur and result
in soot and/or excessive production of carbon monoxide (CO), a color-
less, odorless, toxic gas.
The size and position of the log set is critical to achieve a safe, reli-
able and attractive flame pattern. Any attempt to use a different log
set in the fireplace will void the warranty and will result in incomplete
combustion, sooting and poor flame quality.
1. Remove the six logs from the box and foam packaging. Lay them out
for easy identification during installation.
2. Place rear log on insert tabs (these tabs will penetrate the center of
the log) at the rear of the burner.
3. Place a light (fluffed) layer of embers (rockwool) directly on top of
the port holes in the burner. CAUTION: A 1/4" (6.4mm) air space
between the rockwool and lower base of the rear log needs to be
maintained for combustion air and proper flame aesthetics.
4. Place Log #2 on tab. An air shield is provided for natural gas use only.
For LP conversions, remove the air shield.
5. Place Logs #3, #4 and #5 on tab inserts.
6. Place Log #6 on tab located on right side of firebox. The other end of
the log is placed on the burner.
7. Volcanic stone may be placed along the front edge of the burner, but
not directly over the burner ports.
Insert
Tabs
Rockwool
Figure 26
Figure 27
Log #3
Log
#
Figure 28
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Important!!! Maintain a 1/4" (6.4mm) air
space along the entire length of log.
Log #6
Volcanic Stone
Embers
Log #5
Air Shield
Log Locater
Tab for Log #6
Log
#4
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ravelle 42Ravl42