Lennox Hearth Products RAVELLE 42 Installation And Operation Instructions Manual
Lennox Hearth Products RAVELLE 42 Installation And Operation Instructions Manual

Lennox Hearth Products RAVELLE 42 Installation And Operation Instructions Manual

Direct-vent signature collection
Table of Contents

Advertisement

P/N 775219M Rev. F 08/2011
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775219CF.
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer
(Protects Against Burns)
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . 5
L'information de sûreté importante
[EN FRANÇAIS]
Apposition des mises en garde relatives à la sécurité d'utilisation
Información importante de seguridad
[EN ESPAÑOL]
Colocación de advertencias de seguridad en operación
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
WARNING
• HOT GLASS WILL
CAUSE BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
. . . . . . . . . . . . . 2
. . . . . . . . . . . . 3–4
. . . 5
. . . . . . . . . . . . 3–4
. . . . . . . . . . 5
AVERTISSEMENT
/
• UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
INSTALLATION AND OPERATION INSTRUCTIONS
Direct-Vent
RAVELLE™ 42
MODELS
Portland
US
OTL Report No. 050-S-08c-5
INSTALLER: Leave this manual
with the appliance.
Wait...
DON'T
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
CONSOMMATEUR : Conservez cette
notice pour consultation ultérieure.
AVERTISSEMENT: Assurez-vous de bien suivre les instruc-
tions données dans cette notice pour réduire au minimum
le risque d'incindie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
RAVL42
CONSUMER: Retain this manual
for future reference.
INSTALLATEUR : Laissez cette
notice avec l'appareil.
AVISO
/
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products RAVELLE 42

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS Direct-Vent RAVELLE™ 42 MODELS P/N 775219M Rev. F 08/2011 RAVL42 Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 775219CF. Portland WHAT'S INSIDE Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OTL Report No.
  • Page 2: Table Of Contents

    To receive your FREE SAFETY GUARD, call 1-800-786-7976  To prevent severe burns and injuries, install or visit www.lennox.com (Lennox Hearth Products / Owner Resources) a screen or physical barrier to prevent direct Note: Safety Guards may not be available for some contact with the glass .
  • Page 3 Toutes les parties de votre foyer ¡Todas las partes de la chimenea Lennox Hearth Products deviennent Lennox Hearth Products se ponen EXTRÊMEMENT CHAUDES ! MUY CALIENTES!  Afin d'éviter de vous brûler gravement ou de  Instale una malla o barrera física para evitar vous blesser, installez une grille ou une barrière...
  • Page 4: Important Safety Information

    Important Safety Information L'information de sûreté importante 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal 1. WARNING: Do not operate appliance with the glass front en verre n’est pas en place, est craqué ou brisé. removed, cracked or broken. 2.
  • Page 5: Attaching The Safety-In-Operation

    3 . If you are unable to locate the labels, please call (Figure C) . Choisissez la langue qui est principale- Lennox Hearth Products o al distribuidor de Lennox Lennox Hearth Products or your nearest Lennox ment parlée dans la résidence du propriétaire .
  • Page 6: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Turn off gas and electrical power to the Warranty Information appliance and allow it to cool before Service, and Maintenance cleaning or servicing the appliance. Your gas appliance is covered by a limited Notices lifetime warranty . You will find a copy of the warranty accompanying this manual .
  • Page 7: General Information

    Any modification une maison préfabriquée (mobile) déjà or alteration may result in damage to Lennox Hearth Products, its employees, installée à demeure si les règlements the appliance or dwelling and will void or any of its representatives assume no locaux le permettent.
  • Page 8: Orifice Size/Altitude Adjustment

    . Changing the orifice should only be done by a quali- Institute) gas appliance safety standards . fied service technician . Contact your Lennox Hearth Products dealer for This fireplace has been tested and certified by OMNI -Test Laboratories to proper orifice sizes .
  • Page 9: Pre-Installation

    (valve and pilot assembly) or • Residential installing a conversion kit . Only Lennox Hearth Products conversion kits • Vented vertical and horizontal can be used to convert from NG to LP or LP to NG . Contact your Lennox •...
  • Page 10: Installation

    (756mm) and may create a serious fire, health, or other safety hazard . The Lennox Hearth Products warranty will be voided if one of the fol- lowing occurs: • Installation of any damaged fireplace or vent system component .
  • Page 11: Framing Dimensions

    A 6" (152 mm) header may need to be notched to accommodate vertical INSTALLATION vent pipe . If the fireplace is going to be horizontally vented directly out the back, do not place a stud in line with the wall thimble . If a hearth extension greater than 1"...
  • Page 12: Fireplace Dimensions

    Ravelle™ 42 Fireplace Dimensions Inches (millimeters) 18-9/16 29-3/4 (471) (756) 51-1/4 (1302) Corner Installation Framing Details 10-3/4 (273) 20-3/4 (527) 38-1/4 (972) (1092) 44-1/2 (356) (1130) 72-1/2 (1842) 3-1/2 (127) (89) (51) 47-3/4 (1213) (1041) (864) 35-1/2 (902) ELECTRICAL (762) INLET 18-3/16 (762)
  • Page 13: Raised Installations

    Raised Installations Hearth Extension Considerations The fireplace may be raised by building a platform of sufficient strength to A hearth extension in front of the fireplace is not required; however, to support the fireplace and pipe . When building a raised hearth extension, enhance the appearance of the Ravelle™...
  • Page 14: Facing Installation Considerations

    Facing Installation Considerations The screws should be driven through the cement board into the outer metal skin of the fireplace . The sheetrock (drywall) is then butted up to the Non-combustible cement board (such as Wonderboard, Durock, or Har- cement board . The sheetrock above the fireplace should also be fastened dybacker) must extend 10"...
  • Page 15 . Templates for the various faces may be purchased 30-5/8" from your Lennox Hearth Products dealer or a template may be made of (778mm) plywood using the dimensions listed on this page . If you choose to make a template, 1/8"...
  • Page 16: Face Installation

    2 . Bracket C in the diagram below is installed on the face during the face Face Installation assembly (see instructions included with face) . The captive screws D A number of different faces are available for the Ravelle™ 42 gas fire- on this bracket should be screwed into captive nuts E on the fireplace .
  • Page 17: Vent Installation

    Secure Vent direct-vent pipe by Security Chimneys* may be used with the Application Ravelle 42 gas fireplace . Please see the lists below to verify the components The Ravelle™ 42 gas fireplace, has been tested and listed as a direct- available from each direct-vent pipe manufacturer .
  • Page 18 Direct vent pipe by Security Chimneys or Dura-Vent may be used with with the Ravelle™ 42 gas fireplace . Please see the lists below to verify the Ravelle 42 gas fireplace . Please see the lists below to verify the the components available from each direct-vent pipe manufacturer . All components available from each direct-vent pipe manufacturer .
  • Page 19: Vent Considerations

    Supports: Vent Considerations Horizontal runs of vent must be supported every three feet . Wall straps are available for this purpose . Twist-lock procedure: Four indentations, located on the female ends Pipe Sealing: If Security Chimneys™ pipe is used, then sealant is of pipes and fittings, are designed to slide straight onto the male ends of required at only the first pipe joint attaching the pipe to the flue collar adjacent pipes and fittings by orienting the four pipe indentations so they...
  • Page 20: Horizontal Vent Installation

    IMPORTANT NOTES: IMPORTANT NOTES: 1 . All Ravelle™ 42 gas fireplaces that are horizontally terminated 1 . All Ravelle 42 gas fireplace vertically terminated may only use may only use 8”x 5” Security Chimneys™ or Dura-Vent ® 6-5/8” x 4” Security Chimneys or Dura-Vent direct-vent pipe .
  • Page 21: Flue Restrictors

    . Flue restrictors may need to be installed depending on the vent configuration of your fireplace . The drawings on Page 22 show all the allowable pipe configurations for the Ravelle 42 gas fireplace . To properly install the flue restrictor, find your pipe configuration in the...
  • Page 22: Horizontal Terminations

    Horizontal Terminations Vertical Terminations (Use 8" Direct-Vent Pipe) (Use 6-5/8" Direct-Vent Pipe) The shaded areas in the diagram below show all allowable combinations The shaded areas in the diagram below show all allowable combinations of vent configuration with horizontal terminations . Horizontal sections of straight vertical and offset to vertical (maximum four 45º...
  • Page 23: Exterior Horizontal Vent

    Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
  • Page 24: Brick Panel And Log Set Installation

    Brick Panel and Log Set Installation 6 . Place Log #6 on tab located on right side of firebox . The other end of the log is placed on the burner . 7 . Volcanic stone may be placed along the front edge of the burner, but Brick Panel not directly over the burner ports .
  • Page 25: Electrical Connections

    ELECTRICAL CONNECTIONS * The breaker supplying electricity to the fireplace must be turned off at the electrical panel before any connections are made at the fireplace . * The wire supplying the fireplace should be a minimum of 14 gage and provide 120 Volts at 60 hz .
  • Page 26: Gas Line Installation

    . This appliance can only be operated using propane gas (LP) if a certified fuel conversion kit provided by Lennox Hearth Products is Two pressure taps are provided on the fireplace’s valve to check gas installed by a qualified service technician .
  • Page 27: Movement

    Increasing Efficiency and Hot Air Movement Possible Opening and Grill Locations A number of different options are available to the homeowner to maximize on Cabinet the heat output and air movement to different rooms in the house . Grills: If your Ravelle™ 42 gas fireplace is installed in a cabinet or a chase, heat can be drawn from these enclosures and circulated into the living area by cutting one or two openings covered by a register or Grill .
  • Page 28 The Forced Air Duct System allows you to direct warm air from your Ravelle 42 DV fireplace, using a 150 CFM blower, through six inch ducts into other rooms in the house . It can be ducted either above or next to the Warm air can be drawn off the Ravelle™...
  • Page 29 The blower box may be located in the wall, floor, or ceiling . Ceiling and Wall Mounting: 1 . Fasten the two angled brackets to the side of the face box with the screws provided (see A below) . 2 . Fasten the bracket in these 2.
  • Page 30: Forced Air Duct System

    Duct Assembly: The duct has zero clearance to combustibles . 1 . Remove the cover plate from the top of the fireplace . Save the screws and discard the plate . 2 . Insert the starter ring into the starter ring adaptor and bend the tabs under to secure the ring to the adaptor . See the expanded view below . 3 .
  • Page 31: Forced Air Duct System

    Wiring of the Forced Air Duct System Continued: 2 . Remove the cover over the electrical box at the right lower rear of the fireplace . Run sheathed wire from the fireplace electrical box to the switch box and from the switch box to the blower box . Install the wire clamp in the unused knock-out hole in the fireplace electrical box cover .
  • Page 32: Attaching Safety-In-Operation

    Lennox Hearth Products or your nearest Lennox taire . En cas de doute, collez l’étiquette en anglais . Lennox Hearth Products o al distribuidor de Lennox Hearth Products dealer to receive additional 3 . Si vous ne trouvez pas les étiquettes, veuillez Hearth Products más cercano para recibir etiquetas...
  • Page 33: Operating Instructions

    Note: Dial cannot be turned from "PILOT" to "OFF" unless dial is pushed in slightly. Do not force. CAUTION: YOUR LENNOX HEARTH PRODUCTS GAS APPLIANCE 6 . Wait five (5) minutes to clear out any gas . Then smell for gas, MUST ALWAYS BE OPERATED WITH GLASS IN PLACE.
  • Page 34: Flame Color And Behavior

    10 . After pilot is lit, turn gas control knob counterclockwise SIT Millivolt Gas Valve to "ON ." Knob can only be turned to "ON" if the knob has popped out . 11 . To turn burner on, turn "ON/OFF" rocker switch to "ON" or set the thermostat to the desired temperature above room temperature .
  • Page 35: Air Shutter Adjustment

    Quiet Operation The Ravelle™ 42 gas fireplace has an air shutter control lever located As the Ravelle 42 gas fireplace is burning a number of normal operational at the upper left corner beneath the firebox (see Figure 46) . The lever sounds may be heard .
  • Page 36: Operating Options

    Operating Options Thermostat Wire Wire Size Maximum Length Your Ravelle™ 42 gas fireplace comes equipped with an “ON/OFF” rocker switch used to turn the burner on and off while the pilot light is on . The 12 Gage 100 Feet switch is a round rocker switch located behind the lower door of the 14 Gage 64 Feet...
  • Page 37: Maintenance And Servicing

    Millivolt and System Checks MAINTENANCE AND SERVICING Check Connect Thermostat Meter Read- Test Test Meter Connects WARNING Leads to Should Be Terminals Turn off gas and electrical power to the fireplace Complete 2 & 3 Closed 100 MV and allow it to cool before cleaning or servicing System or More the appliance.
  • Page 38: Opening And Removing Door

    . This replacement • The glass door(s) of this appliance must only be glass door is available from your Lennox Hearth Products dealer . Do not replaced as a complete unit as provided by the use substitute parts or materials .
  • Page 39: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 40: Replacement Parts

    DC (ref. form #750129M) H3123 Flue Restrictor Plates W/Hardware Misc Contact an Lennox Hearth Products dealer to obtain any of these parts. 75259 NP-RAVL30/42 Nail Plates (4 x 12) galvanized Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
  • Page 41 Face Kits Face Kits Classic Arched Required to Complete Face: Insets (ref. form #775253M) (ref. form #775253M) Cat. No. Model Description Cat. No. Model Description 75290 CIF42-BLK Black Face, Classic 75294 AIF42-BLK Black Face, Arched 75292 CIF42-GOLD Gold Face, Classic 75296 AIF42-GOLD Gold Face, Arched...
  • Page 42: Fireplace Labels

    SERIAL RAVELLE™ 42 MODÈLE RAVELLE™ 42 RAVL42 section anglophone de cette étiquette Portland Portland FABRIQUÉ PAR: LENNOX HEARTH PRODUCTS MANUFACTURED BY: Número de Rapport PO BOX 987 LENNOX HEARTH PRODUCTS 050-S-08c-5 Report No. AUBURN, WA., USA 98071 050-S-08c-5 PO BOX 987 AUBURN, WA., USA 98071...
  • Page 43: For Your Safety Read Before Lighting

    LIGHTING LABEL - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. A.
  • Page 44 LIGHTING LABEL - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. •...
  • Page 45 NOTES...
  • Page 46: Product Reference Information

    Fuel Type (Check one) c Natural Gas c Propane Gas (LP) Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products . Consult your local distributor for fireplace code information .

This manual is also suitable for:

Ravl42

Table of Contents