5-3.Setting the Data Transmission Format
In the following format, data will be transmitted:
Header
Code mark
If you specify that the code mark follows bar code data, then data
will be transmitted in the following format:
Number of digits
Header
You may choose whether or not to transmit the code mark and the number of
digits, as well as choosing the data transmission format of the header,
terminator, and bar code data by using bar-coded parameter menus.
In addition, you may define an arbitrary header and terminator from the ASCII
character set (00h to 7Fh) and some control codes keyed in, as described in
Section 5.6.
The default transmission format is shown below.
Bar code data
◆Code Mark
Bar code type
UPC-A
UPC-E
EAN-13
EAN-8
Standard 2 of 5
Interleaved 2 of 5
Code marks for UPC/EAN with supplemental codes are the
same as those for the corresponding UPC and EAN codes.
Number of digits
n1
n1
n2
Terminator
(ENTER)
Code
mark
A
C
E
A
B
FF
H
I
n2
Bar code data
Bar code type
Codabar
Code 39
F
Code 93
Code 128
EAN-128
Z
19
Bar code data
Code mark
Code
mark
N
C M Y
L
K
W
Terminator
Terminator
X