4.3 Coffee dispenser unit

The position of this unit (ref. 21, fig. 4) can be modified
according to the height of the container used.
In fact it is possible to move the mobile dispenser backwards
(ref. 23, fig. 4) and the telescopic dispenser upwards or
downwards (ref. 24, fig. 4). This allows different heights to be
obtained.(see fig. 4).
N.B.: If a container taller than 90 mm is always and
exclusively used, the telescopic dispenser can be removed
altogether (ref. 23, fig. 4), by drawing it downwards.
4.4 Steam/hot water spout (LUXE version)
The steam (ref. 16, fig. 1) and hot water spouts (ref. 11, fig.
1) are equipped with suitable rubber protectors (ref. 14 and 9,
fig. 1) so that they can be easily gripped and moved even
when overheated.
5

- INSTALLATION

Danger
Operation falling within the competence of the
Maintenance technician.
5.1

Connections

Warning
The connection will have to be implemented by observing
the national safety rules
Carry out connections as follows:
-
Check that the surface upon which the machine is placed
is firm and able to withstand the weight.
-
Drill the relevant holes in the surface top (ref. C' and D'
or F', fig. 6), and possibly also the other holes (ref. B
fig. 6 e ref. E', fig. 6 - see N.B.), as indicated in the
drawing.
-
Install the machine on the surface and level it by
adjusting the feet made available for this operation (ref.
A, fig. 5).
-
Connect machine to the drinking water system by way of
the special fitting (ref. C, fig. 5).
WATER AND WASTE CONNECTIONS SHALL
COMPLHY WITH APPLICABLE FEDERAL STATES, OR
LOCAL CODES. (Only for USA and CDN models)
-
Connect to the power mains by way of the relevant cord
(ref. D, fig. 5).
N.B.: It is possible to connect the drip fray (ref. 15, fig. 1)
directly to an outlet by proceeding as follows:
-
drill the surface top as indicated (ref. B', fig. 6);
-
break the removable diaphragm which seals the drip
tray outlet (ref. 15, fig. 1);
-
join a drain tube to the fitting (ref. B, fig. 5), by way of
a suitable hose clamp.