HEATING CAPACITY TABLES

PCG-06-PS
Twi
Two
qa
Pf
°C
°C
m3/h
kW
750
2.28
45
40
648
2.12
588
2
750
2.24
50
40
648
2.07
588
1.98
750
4.37
70
60
648
4.05
588
3.83
TAI:
Air in temperature
Twi:
Fluid in temperature
Qw:
Fluid flow rate in heat exchanger
Dpw: Pressure drop standard coil
Qa:
Air flow
Note: Design and specification are subject to change without prior notice for product improvement.
PCG-08-PS
Twi
Two
qa
Pf
°C
°C
m3/h
kW
846
2.45
45
40
700
2.22
550
1.93
846
2.4
50
40
700
2.16
550
1.89
846
4.68
70
60
700
4.22
550
3.7
TAI:
Air in temperature
Twi:
Fluid in temperature
Qw:
Fluid flow rate in heat exchanger
Dpw: Pressure drop standard coil
Qa:
Air flow
Note: Design and specification are subject to change without prior notice for product improvement.
HYDRONIC CASSETTE
TAI 18℃
Tad
Qw
dPw
Pf
°C
l/h
kPa
kW
27.4
390
2.36
2.07
28
363
2.1
1.92
28.4
342.8
1.86
1.82
27.2
192
0.6
2.04
27.8
177
0.57
1.9
28.3
170
0.53
1.8
36
374.6
2.2
4.14
37.2
347
1.91
3.84
38
328
1.73
3.63
TAI 18℃
Tad
Qw
dPw
Pf
°C
l/h
kPa
kW
26.9
420
2.7
2.21
27.8
380
2.3
2
28.8
330
1.76
1.75
26.7
205
0.8
2.18
27.5
185
0.6
1.96
28.6
162
0.5
1.73
34.9
401
2.5
4.43
36.5
361
2.1
4
38.7
317
1.63
3.41
TAI 20℃
Tad
Qw
dPw
Pf
°C
l/h
kPa
kW
28.5
354
1.98
1.86
29.1
329
1.74
1.73
29.5
312
1.6
1.64
28.4
175
0.557
1.83
29
162
0.491
1.71
29.4
154
0.445
1.61
37
354
1.98
3.91
38.2
329
1.74
3.64
39
311
1.56
3.46
Pf:
Total heating capacity
Tad:
Discharge air temperature
TAI 20℃
Tad
Qw
dPw
Pf
°C
l/h
kPa
kW
28
378.9
2.23
1.99
28.8
342.9
1.9
1.8
29.8
300
1.47
1.58
27.9
186.9
0.7
1.96
28.6
168
0.52
1.74
29.7
148
0.414
1.55
36.1
380
2.3
4.2
37.6
343
1.9
3.73
41
292
1.4
3.32
Pf:
Total heating capacity
Tad:
Discharge air temperature
TAI 22℃
Tad
Qw
dPw
Pf
°C
l/h
kPa
kW
29.6
318
1.64
1.65
30.2
296
1.44
1.54
30.5
281
1.31
1.46
29.5
166.9
0.457
1.62
30.1
146.6
0.406
1.52
30.4
138
0.362
1.42
38.1
335
1.78
3.68
39.3
312
1.58
3.44
40.1
296.6
1.44
3.29
TAI 22℃
Tad
Qw
dPw
Pf
°C
l/h
kPa
kW
29.2
341
1.85
1.77
29.9
308
1.55
1.6
30.8
270
1.23
1.41
29.1
168
0.6
1.74
30.2
149
0.42
1.52
30.7
132
0.4
1.37
37.2
360
2.04
3.97
39.7
319
1.65
3.46
40.6
284
1.33
3.23
11
TAI 24℃
Tad
Qw
dPw
°C
l/h
kPa
30.7
282
1.3
31.3
263
1.14
31.5
250
1.02
30.6
158.8
0.357
31.2
131.2
0.321
31.4
122
0.279
39.2
316
1.58
40.4
295
1.42
41.2
282.2
1.32
TAI 24℃
Tad
Qw
dPw
°C
l/h
kPa
30.4
303.1
1.47
31
273.1
1.2
31.8
240
0.99
30.3
149.1
0.5
31.8
130
0.32
31.7
116
0.386
38.3
340
1.78
41.8
295
1.4
40.2
276
1.26