Ii. Installation; Unit Placement - Lennox Signature XP21 Series Installation And Service Procedure

Heat pump lennox signature xp21 series
Table of Contents

Advertisement

Unit Placement

CAUTION
In order to avoid injury, take proper precaution when lift-
ing heavy objects.
See Unit Dimensions on page 3 for sizing mounting slab,
platforms or supports. Refer to figure 3 for mandatory
installation clearance requirements.
POSITIONING CONSIDERATIONS
Consider the following when positioning the unit:
Some localities are adopting sound ordinances based
D
on the unit's sound level registered from the adjacent
property, not from the installation property. Install the
unit as far as possible from the property line.
When possible, do not install the unit directly outside
D
a window. Glass has a very high level of sound trans-
mission. For proper placement of unit in relation to a
window see the provided illustration in figure 5, detail
A.
CLEARANCE ON ALL SIDES
6 (152)
12 (305)
36 (914)
MINIMUM CLEARANCE BETWEEN
TWO UNITS
XP21

II. INSTALLATION

INCHES (MILLIMETERS)
ACCESS PANEL
NOTES:
CONTROL PANEL
D
ACCESS
LOCATION
30 (762)
D
LINE SET
CONNECTIONS
24 (610)
Figure 3. Installation Clearances
PLACING UNIT ON SLAB
When installing unit at grade level, the top of the slab
should be high enough above grade so that water from
higher ground will not collect around the unit. The slab
should have a slope tolerance as described in figure 5, de-
tail B.
NOTE
If necessary for stability, anchor unit to slab as de-
scribed in figure 5, detail D.
ELEVATING THE UNIT
Units are outfitted with elongated support feet as illustrated
in figure 5, detail C.
If additional elevation is necessary, raise the unit by ex-
tending the height of the unit support feet. This may be
achieved by using a 2−inch (50.8mm) Schedule 40 female
threaded adapter.
The specified coupling will fit snuggly into the recessed
portion of the feet. Use additional 2−inch (50.8mm) Sched-
ule 40 male threaded adaptors which can be threaded into
the female threaded adaptors to make additional adjust-
ments to the level of the unit.
NOTE
Keep the height of extenders short enough to en-
sure a sturdy installation. If it is necessary to extend
further, consider a different type of field−fabricated frame-
work that is sturdy enough for greater heights.
CLEARANCE TO
ONE
OF THE
OTHER THREE SIDES MUST BE 36
INCHES (914MM).
CLEARANCE TO
ONE
OF THE
REMAINING TWO SIDES MAY BE 12
INCHES (305MM) AND THE FINAL
SIDE MAY BE 6 INCHES (152MM).
ACCESS PANEL
LINE SET
CONNECTIONS
Page 8
MINIMUM CLEARANCE
ABOVE UNIT
48 (1219)
REAR VIEW OF UNIT