Lennox Signature XP21 Series Installation And Service Procedure page 37

Heat pump lennox signature xp21 series
Table of Contents

Advertisement

Heat Pump Control
icomfortt
icomfortt
LEDs
Thermostat
Thermostat
DS15
DS13
Display
Display
Yellow
Red
4 flashes
Critical Alert
then
Off
Code 404
pause
5 flashes
Critical Alert
then
Off
Code 405
pause
6 flashes
Critical Alert
then
Off
Code 406
pause
7 flashes
Critical Alert
then
Off
Code 407
pause
8 flashes
Critical Alert
then
Off
Code 408
pause
9 flashes
Moderate/
then
Critical Alert
Off
pause
Code 409
Fast simultaneous flashing of DS11,
DS13, DS14 and DS15
1. Pause duration is two (2) seconds.
2. Fast flash duration is 1/2 second. Slow flash duration is one (1) second.
3. Initially a moderate status is displayed and is escalated to critical if alarm exists for more than 10 minutes.
Possible
Possible
Condition
Condition
Cause(s)
Cause(s)
Compressor has
a locked out due
to run capacitor
short, bearings
Locked rotor
are seized,
excessive liquid
refrigerant.
Compressor has
an open circuit
due to power dis-
connection, fuse
Open circuit
is open or other
similar condi-
tions.
Current not
Open start
sensed by Start
circuit
transformer.
Current not
Open run
sensed by run
circuit
transformer.
Welded
Compressor
contactor
always runs
Secondary
24VAC is below
3
low voltage
18VAC.
OEM Mode
Factory test mode.
Solution
Solution
1
Run capacitor has failed.
2
Low line voltage (contact utility if voltage at
disconnect is low).
S
Check wiring connections
3
Excessive liquid refrigerant in the compressor.
4
Compressor bearings are seized.
1
Outdoor unit power disconnect is open.
2
Unit circuit breaker or fuse(s) is open.
3
Unit contactor has failed to close.
S
Check compressor contactor wiring and
connectors
S
Check for compressor contactor failure
(burned, pitted or open)
S
Check wiring and connectors between supply
and compressor
S
Check for low pilot voltage at compressor
contactor coil
4
High pressure switch is open and requires
manual reset.
5
Open circuit in compressor supply wiring or
connections.
6
Unusually long compressor protector reset time
due to extreme ambient temperature.
7
Compressor windings are damaged.
S
Check compressor motor winding resistance
1
Run capacitor has failed.
2
Open circuit in compressor start wiring or
connections.
S
Check wiring and connectors between supply
and the compressor S terminal
3
Compressor start winding is damaged.
S
Check compressor motor winding resistance
1
Open circuit in compressor start wiring or
connections.
S
Check wiring and connectors between supply
and the compressor R terminal
2
Compressor start winding is damaged.
S
Check compressor motor winding resistance
1
Compressor contactor failed to open.
2
Thermostat demand signal not connected to
module.
1
Control circuit transformer is overloaded.
2
Low line voltage (contact utility if voltage at
disconnect is low).
S
Check wiring connections
Page 37
Clearing Sta-
Clearing Sta-
tus
tus
Clears after
power reset or
four normal
compressor
cycles.
Clears after one
normal com-
pressor run
cycle or power
reset.
Clears when
amperage is de-
tected in RUN
and START
sensors, or after
power reset.
Clears when
amperage is de-
tected in RUN
and START
sensors, or after
power reset.
Clears after one
normal com-
pressor run
cycle or after
power reset.
Clears after
voltage is high-
er than 20VAC
for two sec-
onds, or after
power reset.
XP21