F-88
CURRENT TRANSDUCER REMOVAL AND REPLACEMENT (continued)
PROCEDURE
1. Remove input power to the V350-PRO.
2. Using a 5/16" nut driver remove the case wrap-
around cover.
3. Perform the Input Filter Capacitor Discharge
Procedure detailed earlier in this section.
Plastic
Nut
TROUBLESHOOTING & REPAIR
FIGURE F.40. – CASE BACK SCREW LOCATIONS
5/16" Mounting Screws
V350-PRO
4. Using a 5/16" nut driver remove the four screws
from the bottom and right side of the rear assem-
bly. See Figure F.40.
REAR
OFF
O FF
O FF
F-88