Input Rectifier (Close-Up) - Lincoln Electric INVERTEC V350-PRO Service Manual

Lincoln electric invertec v350-pro
Hide thumbs Also See for INVERTEC V350-PRO:
Table of Contents

Advertisement

F-81
INPUT RECTIFIER REMOVAL AND REPLACEMENT (continued)
9. Apply a thin coat of Penetrox A-13 heatsink com-
pound to the point of contact between the input
rectifier and the mounting surface.
10. Secure the new input bridge into its proper posi-
tion with the two 3/16"in. allen mounting screws
previously removed. Torque to 44 inch pounds.
Small Lead "H1"
To Auxiliary Transformer
TROUBLESHOOTING & REPAIR
FIGURE F.37. – INPUT RECTIFIER (CLOSE-UP)
3/16" ALLEN
C
B
A
11. Reconnect the previously removed leads to their
proper locations. Torque to 31 inch pounds.
12. Cover the input rectifier and its six terminals with
silicon sealant.
13. Replace the case wraparound cover.
BOLTS
FRONT
REAR
V350-PRO
#207
#207A
#209
Small Lead "A"
To Circuit Breaker
F-81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents