This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-Flex)Venting Kits and
components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct
Vent system (Model DV-GS Series), Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
Simpson Dur a-Vent for Masonr y Chimney Conver sion Kits may be used with this appliance Use your existing masonry chimney and route
the exhaust gases intake air through the side of the masonry chimney. Use Simpson Dura-Vent kit numbers 46DVA-KMC or 46DVA-KCT.
Termination Cap, Kingsman/Dura-Vent adapter, and 4" flex are sold separately.
Simpson Dur a-Vent for Factor y built metal Chimney Conver sion Kits may be used with this appliance. Use your existing through the ceil-
ing, wood stove chimney and route the exhaust gases and intake air through the existing wood burning metal chimney. Use Simpson Dura-Vent
Kit numbers 46DVA-KCA for 6 5/8" to 8 5/8" OD sized chimney, 46DV-KCB for 8 3/4" to 10 1/2" OD sized chimneys and 46DVA-KCC for
10 5/8" to 13" OD sized chimneys. Kits 931, 932, and 933 include a cap adapter and Retro Connector. Termination Cap, Kingsman/Dura-Vent
adapter, and 4" flex are sold separately.
RIGID OR HARD PIPE
When using Simpson Duravent, AmeriVent pipe, ICC Excel Direct, Metal Fab Sure-Seal DV and or Selkirk Direct Temp a Duravent hardpipe adapter must be
used (p p art # ZDVDFA for fireplaces and part # ZDVDKA for Stoves, Serenity and ZDV3624B). Follow installation instructions provided by Simpson
Duravent/AmeriVent/Selkirk Direct Temp, ICC Excel Direct, Metal Fab Sure-Seal DV for installation of pipe and adhere to the clearance to combustibles provided
in this manual. Apply a bead of Mill Pac high temp sealant to all joints of pipes, adapters and termination, when using Kingsman Flex(Z-Flex)Venting venting and
Simpson Duravent venting.
NOTE: Increase framing depth by one inch when using hardpipe.
WARNING: DO NOT mix parts from different systems unless stated in the manual.
Flex Pipe Venting
Flex pipe is shipped in unexpanded length. When installing pipe expand the lengths. Pipe can be expanded to twice their lengths e.g. 4ft. to
8ft. Fully extend pipe and cut off remaining pipe.
Do not use more than 2 couplers to extend short pipes. Single sections are preferred in an installation attaching at the fireplace and termina-
tion.
Place the spring spaces provided approximately every two feet to stabilize 4" flex in the center of 7" flex. When forming bends place spring in
bend or before and after. (See Fig. 1).
Horizontal runs require support metal straps every 2 feet. In off set installation support straps should be used to stabilize pipe.
Expand 4" and 7" flex pipe to the point that the 7" protrudes approximately 2 to 3 inches past outer wall and the 4" flex protrudes approxi-
mately 2 to 3 inches past the 7" flex. See Fig. 1. Attach the 4" pipe to the termination first and secure with sealant and four screws then
attach the 7" flex to the termination with caulking and four screws. Termination may then be moved back to the outer wall and attached to
home screwing into the framing. Silicone around termination to waterproof. If siding shield is going to be used attach this using same
attaching hole as the top of termination after termination has been caulked for water proofing.
Use Hi Temp Sealant
Apply a bead of mill pac high temp sealant to all joints and use four screws to secure
sections of pipe
.

General Vent Installation Information

each pipe at fireplace, termination and any joint if joining any
NOTE: It is critical to the proper and safe
operation of this fireplace that on all connec-
tions the inner liner and the outer casing are
both caulked with liberal amounts of sealant.
Do not use any kind of tape or silicone other
than that recommended in this manual. Mill
Pac Sealant