MQHBZDV4236/MQRB4236 - HOW TO INSTALL CLEAN VIEW KIT (CVCK)
CAUTION: When using CVCK DO NOT INSTALL a Louver assembly
1. Install optional Fan Kit (See Fan Instruction)
2. Fold two standoffs up into position & mount with supplied Screws. (Fig. 1)
3. Hang CVCK on top of fireplace retainer tabs and rotate down into position. (Fig. 2)
4. Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
5. Using four supplied #6 screws, fasten CVCK kit to the inside frame of unit
6. Kit is supplied with 2 valve extension knobs. Align the notches and slide the extensions onto the valve knobs.
7. DO NOT brick or tile beyond the inside area of the CVCK kit to allow for removal of door.
8. Install optional pull screen system: First slide curtain onto rods and slide round end of rod into side post Ref: A, using 1/2" DT screws, mount the
flattened end of rod to the bottom side of the rod hanger bracket (Ref: B). Repeat this step for the opposite side.
MQHBZDV 4236 - Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
Side (from standoffs)
Floor
Ceiling (from bottom of fireplace) 60 inches/150 cm
Top (from standoffs)
Top of 90 degree bend in Minimum
Enclosure of 45 to 46 inches
Top of 90 degree bend in
Enclosure over 46 inches
Top of Horizontal Pipe
Side & Bottom of Horizontal Pipe 1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
Vertical Vent Pipe
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
5 inches/128 mm / All Vent Systems
2 1/2 inches/64 mm / All Vent Systems
1 1/2 inches/38 mm / All Vent Systems
1 inch/25.5mm / Kingsman Vent Systems
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp
Systems
16
Note: Additional Access for
gasline installation and
Fan Electrical installation!
When CVCK kit is
installed in framing
remove 2 screws from the
right and left side of bot-
tom panel Ref: C. Once
screws are removed, bot-
tom panel can be rotated
forward for access to gas
valve and fan system.
(NOTE -Floor) if installing the
appliance directly on carpeting
or other combustible materials
other than wood flooring, the
appliance shall be installed on
a metal or wood panel, the full
width and depth of the
appliance. Carpet may extend
1 inch above the floor of
appliance.
For units with CVCK (Clear
View Circulating Kit) see
framing with CVCK to
establish floor heights