Symptom-to-FRU index

Error messages

Sym ptom o r error
Device address conflict.
Allocation error for device.
Failing bits: nnnn.
Invalid system configuration
data.
I/O device IRQ conflict.
Operating system not found.
Hibernation error.
Fan error.
Thermal sensing error.
5 6
ThinkPad R40
FRU o r actio n, in sequence
1. Load " Setup D efaults" in
IBM BIOS Setup U tility .
2. Backup battery.
3. System board.
1. Load " Setup D efaults" in
IBM BIOS Setup U tility .
2. Backup battery.
3. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. Load " Setup D efaults" in
IBM BIOS Setup U tility .
2. Backup battery.
3. System board.
1. Check that the operating
system has no failure and is
installed correctly.
2. Enter IBM BIOS Setup
U tility and see w hether
the hard-disk drive and
the diskette drive are
properly id e n tifie d .
3. Reset the hard-disk drive.
4. Reinstall the operating
system.
5. Diskette drive.
6. Hard-disk drive.
7. System board.
1. Restore the system
c o n figura tion to w hat it
w as before the com puter
entered hibernation m ode.
2. If memory size has been
changed, re-create the
hibernation file.
Fan.
System b o ard.