Sony DCR-TRV230E Service Manual page 192

Digital video camera recorder
Hide thumbs Also See for DCR-TRV230E:
Table of Contents

Advertisement

5. VIDEO OUT Y, Chroma Level Check (VC-254 board)
Mode
VTR stop
Signal
No signal
Measurement Point
Video terminal of AUDIO/VIDEO jack
(75Ω terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 307 ± 18mV
Burst level: B = 300 ± 18mV
Adjusting method:
Order Page Address Data
1
0
01
01
2
D
11
10
3
3
0C
02
4
5
6
3
0C
00
7
D
11
00
8
0
01
00
A
H
Fig. 5-3-12.
Procedure
Set the data.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the sync signal level
(A) satisfies the specified value.
Check that the burst signal level
(B) satisfies the specified value.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data.
6. Hi8/Standard8 Y/C Output Level Setting
(VC-254 board)
Set the Y/C signal output level during the Hi8/Standard8 playback
mode.
Mode
Signal
Adjustment Page
Adjustment Address
Note: Perform this adjustment when IC2201 or IC4901 is replaced.
Adjusting method:
Order Page Address Data
1
0
01
2
D
10
3
6
6F
4
6
7F
5
F
67
6
F
68
7
8
F
67
9
F
68
10
6
6F
11
D
10
12
0
01
B
5-51
VTR stop
No signal
F
67, 68
Procedure
01
Set the data.
02
Set the data, and press PAUSE
button.
01
Set the data.
Check that the data.
When the data is "00", proceed
to step 8.
When the data is "03", proceed
to step 5.
65
Set the data, and press PAUSE
button.
72
Set the data, and press PAUSE
button.
Proceed to step 10.
A0
Set the data, and press PAUSE
button.
B8
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents