1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2: Switch setting:
LCD panel ........................................................................... Close
Note3: CF-079 board: DCR-TRV230E/TRV235E/TRV325E/TRV330E
CF-080 board: DCR-TRV430E/TRV530E
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1108 of VC-254 board.
Connect the Measuring Instruments via the CPC-13 jig (J-6082-
443-A).
The following table shows the Pin No. and signal name of CN1108.
Pin No.
Signal Name
1
SWP
2
AFC F0
3
BPF MONI
4
FO ADJ RF IN
5
PB RF
6
REG GND
7
RF AGC OUT
8
VC RF SWP
9
EVF VR (*1), COM DC (*2)
10
EVF VB (*1), N.C. (*2)
*1 : CF-079 board (Part No. suffix: 11)
CF-080 board (Part No. suffix: 11 or 12)
*2 : CF-079 board (Part No. suffix: 12 or later)
CF-080 board (Part No. suffix: 13 or later)
Table 5-1-10.
CN1108
1
20
Remove the
CPC lid (BT)
MI screw (M2 × 4) (H)
Fig. 5-1-13.
Pin No.
Signal Name
11
VCO
12
EVF VG
13
DV RF SWP
14
RF IN
15
CAP FG
16
RF MON
17
TMS
18
TCK
19
TDO
20
TDI
1. VCO Adjustment (CF-079/080 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
D
92
3
D
92
4
D
92
5
6
7
8
D
93
9
0
01
Note: Refer to "Table 5-4-1. Hexadecimal-decimal Conversion Table".
5-26
Camera
Arbitrary
Pin qa of CN1108 of VC-254 board
(VCO)
Frequency counter
D
92, 93
f = 15625 ± 30Hz
Procedure
01
Set the data.
Change the data and set the VCO
frequency (f) to the specified value.
Press PAUSE button.
Read the data, and this data is
named D
.
92
Convert D
to decimal notation,
92
and obtain D
'. (Note)
92
Calculate D
' using following
93
equations (Decimal calculation)
When D
' 24
92
D
'= D
'–24
93
92
When D
'< 24
92
D
'= 0
93
Convert D
' to a hexadecimal
93
number, and obtain D
93
D
Set the data, and press PAUSE
93
button.
00
Set the data.
. (Note)