INNOVATIVE HEARTH PRODUCTS • SEE-THROUGH POWER VENT DV GAS FIREPLACES (DRT63STYN) • CARE AND OPERATION INSTRUCTIONS

MAINTENANCE

(See Maintenance Schedule, Page 22)
Refer to the maintenance schedule for
maintenance tasks, procedures, frequency and
by whom they should be performed. Always
verify proper operation of the appliance after
servicing.
WARNING
Turn off gas and electrical power
to the fireplace and allow it to
cool before cleaning or servicing
the appliance.
CAUTION: Wear gloves and safety
glasses for protection while doing
required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne
adé-quatement une fois l'entretien
terminé.
Always turn OFF gas to the pilot before
cleaning. Before relighting, refer to the
lighting instructions in this manual.
Instructions are also found on a pull-out
panel located in the control compart-
ment.
Inspect Venting System
The appliance and venting system should be
thoroughly inspected before initial use and
at least annually by a qualified service techni-
cian (inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged). Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Glass Cleaning
(For detailed glass door assembly removal/
installation instructions, see Page 12 .)
Note: Clean glass after first two weeks of
operation (after burn-in period is over) and
then only when necessary and ONLY WHEN
THE APPLIANCE IS COOL. Wipe surface with
clean, dampened, soft cloth. Follow with dry,
soft towel as desired. Take care not to scratch
the glass surface.
IMPORTANT: Do not use abrasive
cleaners on glass. Never clean the glass
when it is hot.
Clean the glass periodically, to remove any
buildup caused by the following:
• Filmy coating (during initial use after instal-
lation). Initial curing of the high temperature
paint and burning off of lubricants used in
the manufacturing process may result in a
filmy coating on the glass.
• Dusty or dirty buildup. It is normal for con-
densation and fog to form on the inside of
the glass when first starting the appliance.
This condensation and fog will usually
disappear within a few minutes; however,
over time the moisture can cause lint, dust,
and other airborne particles to cling to the
glass surface.
• White coating. A white coating may form
on the glass as a result of impurities and
minerals in the fuel.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances. The follow-
ing cleaning solutions are approved for use to
clean the glass:
• Non-ammonia based household cleaner
• 50% white vinegar and 50% water
• Gas fireplace/stove glass cleaner
Inspect Glass Gasket
Visually inspect the gasket on the backside of the
glass enclosure panels. The gasket surface must
be clean, free of irregularities and seated firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming
or brushing at least twice a year. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is
important that control compartments, burners
and circulating air passageways of the appliance
be kept clean.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Clean Logs and Burner
Carefully remove the logs (use care when han-
dling the fiber logs, as they become quite fragile
after curing). Vacuum out any foreign matter
(lint, carbon, etc.) on the burner. Ensure the
burner ports are "open." Remove any carbon
deposits from the under side of the logs using
a vacuum cleaner, or a soft bristled brush (i.e.
paint brush).
Note: Improper positioning of logs can create
carbon build-up and will alter the performance
of the appliance.
Replacing Logs
If the logs become damaged by accident or
improper handling and need replacement,
use only the proper replacement logs from
manufacturer (see Pages 17, 25, and 26 for
ordering information).
Reinstall Embers, Volcanic Stone,
and Logs
Carefully follow placement instructions on
Pages 13–15). All logs should fit onto cor-
responding pins and/or log stoppers. This will
ensure a proper flame and safe combustion.
Inspect Wiring
Refer to wiring diagram on Page 17.
CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous operation.
Verify proper operation after servicing.
ATTENTION: Au moment de l'entretien des
commandes, étiquetez tous les fils avant
de les débrancher. Des erreurs de cáblage
peuvent entraîner un fonctionnement
inadéquat et dangereux.
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include terminals at the valve.
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the flame shown in Figures 21 and
22 and as described in "Flame Appearance and
Sooting" on Page 16. The homeowner must
contact a qualified service technician at once
if any abnormal condition is observed.
Small Area Paint Touch-up
Only use a factory supplied paint kit for touch-
ups. Paint is available at your local authorized
Innovative Hearth Products dealer. Never
attempt to paint a hot fireplace.
If the surface later becomes stained or marred,
it may be lightly sanded and touched up with
spray paint.