If the optional fan or blower is installed, the junction box must be electrically connected and grounded in ac-
cordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical Code
in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.
1.5

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
MINIMUM INLET: Gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column
for propane.
MAXIMUM INLET: Gas pressure is 7 inches water column for natural gas and 13 inches water column for
propane. When the valve is set to "HI", the manifold pressure under fl ow conditions is 3.5 inches water column
for natural gas and 10 inches water column for propane. When the appliance is installed at elevations above
4,500ft, and in the absence of specifi c recommendations from the local authority having jurisdiction, the certi-
fi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
MAXIMUM INPUT: Is 11,500 BTU/hr for natural gas.
MAXIMUM OUTPUT: Is 8,600 BTU/hr at an effi ciency of 75%.
MAXIMUM INPUT: Is 11,000 BTU/hr for propane.
MAXIMUM OUTPUT: Is 8,250 BTU/hr at an effi ciency of 75%.
Provide adequate accessibility clearance for servicing and operating the appliance.
Never obstruct the front opening of the appliance.
RATING LABEL LOCATION: The rating label is located behind the control door and is chained to the appli-
ance. DO NOT REMOVE.
1.6

CARE OF GLASS

DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.
Buff lightly with a clean dry soft cloth. Clean the glass after
the fi rst 10 hours of operation with a recommended fi replace
glass cleaner. Thereafter clean as required. If the glass is not
kept clean permanent discoloration and / or blemishes may
result.
W415-0825 / 07.06.09
WARNING
!
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.