2. Technical Description

150
3. Mounting, Installation, Minimum Clearances
The heater must be installed in a horizontal position on
a vertical wall as shown in the illustration.It is permissi-
ble to mount the heater to a wooden wall.
Ensure that air can enter and leave the heater freely, at
the inlets below and the outlets above
The heater must be installed in such a way that it is out
of arm's reach of a person in the tub or shower The
heater must not be installed directly under a wall socket
outlet.
The electrical connection box must be accessible after
the heater has been mounted. Be careful of flammable
objects!
It is absolutely necessary that the minimum clearances
indicated in the mounting diagram be maintained. Be-
yond that, a clearance space of at least 500 mm is to
be provided in front of the appliance.

3.1 Wall Mounting

IMPORTANT- The original wall mounting bracket
supplied, located at the back of the heater, must be
used.
Remove the bracket from the
back of the device by pressing
the springs on each side.
Drill the fixing holes for the wall
mounting bracket.
Firmly secure bracket to the wall
using suitable screws.
Insert heater in wall bracket making use of the slots
on the back of the heater.
Snap heater in place at the top of the wall bracket.
www.dimplex.de/en
EPX 500, EPX 750, EPX 1000, EPX 1500, EPX 2000, EPX 2500
150
430
150
.

4. Electrical Connection

It is imperative that the current regulations acc. to VDE
0100 Part 701 as well as the relevant installation
instructions be adhered to. The heaters are fitted with a
power supply cable without plug. The supply cord must
be connected to a connection box dedicated to the
heater. The hardwired electrical installation must be
provided with a disconnect device with a contact gap of
at least 3 mm at each pole (e.g. automatic circuit
breaker).
INDPGEELRG · 07/14/B · 07/14/B
Drilling dimensions in mm (front view)
150
118
A
255
Type
Rated Power
EPX 500
500 W
EPX 750
750 W
EPX 1000
1000W
EPX 1500
1500W
EPX 2000
2000W
EPX 2500
2500 W
214
150
141
430
184
105
150
65
A (mm)
116
286
286
354
526
526
EN-9