4.3. REQUIREMENTS FOR CONNECTING TO THE HEATING SYSTEM

It is allowed to fit in the boiler by qualified technicians who are aware of all requirements and
who give guarantees on their job, and every time consults our boiler operating manual. Our product
is not very similar to previous structures. Therefore what fits to other boilers does not fit to it.
For instance, boilers where combustion runs below a firebox, it is recommended an intense return of
the heated flow. It does not fir to our coiler.
If up-to-date elements of heating systems in the connecting diagrams of other boilers are used very
diversely and various and complicated connection diagrams are recommended we recommend only
several simple, cheap and justified diagrams.
During fitting procedure of supplement elements, please read the manufacturer requirements and
follow them:
1.
According to recommendations of thermal valve manufacturers, set pre-flow valves
according to the instructions of the heating system design (if it is not the case, then at 1.5 or 1).
2.
Do not exceed heat flow through the floor temperature with floor heating automatic
elements (recommendations of manufacturers: 28 – 35ºC).
3.
Upon fitting three-stage or four-stage mixing valves and a circular pump so that elements
of the boiler and heating would not be shunted mount on a large ring of the house heating system. Preferably
on a reversible flow pipe.
4.
As it usually happens, do not shunt elements of the boiler and heating in parallel to a hot
water heater connected to the boiler (a balance valve is required when connecting a hot water heater in
parallel).
Maintain the temperature sufficient to a good boiler operation (70 † 85ºC).
5.
6.
Follow the recommendations of the chimney flue insert producer.
7.
It is not allowed to fit the chimney flue closing valve. To reduce its draught, use our or
other producers‟ self-intake air valves.
8.
Take care of proper ventilation in a boiler room.
Every time when fitting our solid fuel boiler look at the technical certificate
9.
additions and recommendations are possible).